A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Self-expanding transcatheter aortic valve replacement using alternative access sites in symptomatic patients with severe aortic stenosis deemed extreme risk of surgery. | LitMetric

Objectives: The CoreValve Extreme Risk US Pivotal Trial enrolled patients with symptomatic severe aortic stenosis deemed unsuitable for surgical aortic valve replacement. Implants were attempted using transfemoral access (n = 489) or an alternative access (n = 150). In present analysis, we sought to examine the safety and efficacy of CoreValve transcatheter aortic valve replacement using alternative access.

Methods: The present study included 150 patients with prohibitive iliofemoral anatomy who were treated with the CoreValve transcatheter heart valve delivered by way of the subclavian artery (n = 70) or a direct aortic approach (n = 80). The echocardiograms were read by an independent core laboratory. The primary endpoint was all-cause mortality or major stroke at 12 months.

Results: The preoperative aortic valve area was 0.72 ± 0.27 cm(2) and mean aortic valve gradient was 49.5 ± 17.0 mm Hg. After the transcatheter aortic valve replacement, the effective aortic valve area was 1.82 ± 0.64 cm(2) at 1 month and 1.85 ± 0.51 cm(2) at 12 months. The mean aortic valve gradient was 9.7 ± 5.8 mm Hg at 30 days and 9.5 ± 5.7 mm Hg at 12 months. The death or major stroke rate was 15.3% at 30 days and 39.4% at 12 months. The individual rate of all-cause mortality and major stroke was 11.3% and 7.5% at 30 days and 36.0% and 9.1% at 12 months.

Conclusions: These data demonstrate that the CoreValve transcatheter heart valve delivered by an alternative access provides a suitable alternative for treatment of extreme risk patients with symptomatic severe aortic stenosis, who have prohibitive iliofemoral anatomy and no surgical options.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtcvs.2014.07.020DOI Listing

Publication Analysis

Top Keywords

aortic valve
32
valve replacement
16
aortic
12
transcatheter aortic
12
alternative access
12
severe aortic
12
aortic stenosis
12
extreme risk
12
corevalve transcatheter
12
major stroke
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!