A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Results of the U.S. Food and Drug Administration continued access clinical trial of the GORE HELEX septal occluder for secundum atrial septal defect. | LitMetric

Objectives: This report describes the immediate, 1-, and 5-year follow-up results of the U.S. Food and Drug Administration Continued Access clinical trial of the GORE HELEX Septal Occluder (W. L. Gore & Associates, Inc., Flagstaff, Arizona) for closure of secundum atrial septal defect.

Background: The trial was conducted between May 2003 and August 2006 to allow continued enrollment in a trial of the investigational device during review of data from the Pivotal Trial. Devices with hydrophilic coating on the expanded polytetrafluoroethylene to improve echocardiographic visualization were first used in this trial.

Methods: A total of 137 devices were implanted in 137 patients at 13 US institutions. Evaluations were scheduled at 1, 6, and 12 months for the initial trial and at 36 and 60 months for a later extension of the trial in those who consented to longer term evaluations.

Results: Twelve-month follow-up was completed on 122 of 126 patients with implantations, and 5-year follow-up on 83 of 95 patients who agreed to the trial extension. The overall clinical success rate was 96.7%, and the major adverse event rate 3.6%. Wire frame fractures were seen in 11.7% of patients with no clinical symptoms. A trivial, clinically insignificant leak was seen, or could not be ruled out, in 26.6% of patients at the 5-year evaluation, but no clinically significant leaks were seen. No patient experienced an erosion or sudden catastrophic event.

Conclusions: The immediate, 1-, and 5-year follow-up outcomes of the Continued Access clinical trial continue to demonstrate that the GORE HELEX Septal Occluder is a safe and effective transcatheter occluder for repair of ostium secundum atrial septal defect.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcin.2014.01.169DOI Listing

Publication Analysis

Top Keywords

continued access
12
access clinical
12
clinical trial
12
gore helex
12
helex septal
12
septal occluder
12
secundum atrial
12
atrial septal
12
5-year follow-up
12
trial
9

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!