Assessment of cell viability after manipulation with insulator-based dielectrophoresis.

Electrophoresis

Microscale Bioseparations Laboratory, Biomedical Engineering Department, Rochester Institute of Technology, Rochester, NY, USA.

Published: July 2015

The effects of insulator-based DEP (iDEP) manipulation on cell viability were investigated by varying operating conditions and the shape of the insulating structures. Experiments were conducted with Escherichia coli, Bacillus subtilis, and Saccharomyces cerevisiae cells by varying the applied potential (300-1000 V), exposure time (1-4 min), and composition of the suspending medium (0-10% glucose); using devices made from polydimethylsiloxane. Cell viability was quantified employing Trypan blue staining protocols. The results illustrated a strong decrease in cell survival at higher applied electric potentials and exposure times; and an increase in cell viability obtained by increasing suspending medium osmolality. The composition and structure of the cell wall also played a major role on cell survival, where prokaryotic Gram-positive B. subtilis was the most resilient cell strain, while eukaryotic S. cerevisiae had the lowest survival rate. Due to the popularity of iDEP in applications with biological cells, characterizing how iDEP operating conditions affect cell viability is essential.

Download full-text PDF

Source
http://dx.doi.org/10.1002/elps.201400331DOI Listing

Publication Analysis

Top Keywords

cell viability
20
cell
8
operating conditions
8
suspending medium
8
cell survival
8
viability
5
assessment cell
4
viability manipulation
4
manipulation insulator-based
4
insulator-based dielectrophoresis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!