Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/MCG.0000000000000195 | DOI Listing |
PLoS One
January 2025
Cardiovascular Center, Division of Cardiology, Korea University Guro Hospital, Seoul, Republic of Korea.
Background: The phase angle (PhA) in bioelectrical impedance analysis (BIA) reflects the cell membrane integrity or body fluid equilibrium. We examined how the PhA aligns with previously known markers of acute heart failure (HF) and assessed its value as a screening tool.
Methods: PhA was measured in 50 patients with HF and 20 non-HF controls along with the edema index (EI), another BIA parameter suggestive of edema.
Clin Obes
January 2025
Orthopädische Klinik und Poliklinik, Rostock, Germany.
Pathologic values of body mass index (BMI), body weight, and waist circumference correlate with higher absolute and lower relative trunk strength. Whether waist-to-height ratio (WHtR) is appropriate for showing trunk strength differences in people with obesity and whether a continuous linear relationship exists between the increase in obesity and trunk strength is unknown. This retrospective cross-sectional study included 1174 subjects (1114 men and 60 women).
View Article and Find Full Text PDFCancer Chemother Pharmacol
January 2025
Department of Molecular and Internal Medicine, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan.
Background: The expression of anti-programmed cell death ligand-1 (PD-L1) in tumors is widely used as a biomarker to predict the therapeutic efficacy of anti-programmed cell death-1(PD-1)/PD-L1 antibodies. However, the predictive accuracy of this method is limited. High-mobility group box 1 (HMGB1) is known to modulate cancer immunity.
View Article and Find Full Text PDFJ Pers Med
January 2025
Eye Unit-Department of Medicine, Surgery, Dentistry "Scuola Medica Salernitana", University of Salerno, via S. Allende, 84081 Baronissi, Italy.
Choroidal thickness (ChT) is an important measurement for evaluating eye and systemic disorders, but it is influenced by numerous elements, especially axial length (AL). It is known that the presence of a linear relationship between ChT and AL exists, but recently it has been shown that the AL measurement obtained with the current optical biometry is not very precise and needs to be corrected. This study aimed to verify if a similar correlation also persists with this corrected AL (ALc).
View Article and Find Full Text PDFBiosensors (Basel)
January 2025
NanoTech Laboratory, School of Engineering, Faculty of Science and Engineering, Macquarie University, Sydney, NSW 2109, Australia.
Timely ketone detection in patients with type 1 diabetes mellitus (T1DM) is critical for the effective management of diabetic ketoacidosis (DKA). This systematic review evaluates the current literature on breath-based analysis for ketone detection in T1DM, highlighting nanotechnology as a potential for a non-invasive alternative to blood-based ketone measurements. A comprehensive search across 5 databases identified 11 studies meeting inclusion criteria, showcasing various breath analysis techniques, such as semiconducting gas sensors, colorimetry, and nanoparticle-based chemo-resistive sensors.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!