A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

HPLC-UV method for quantifying etoposide in plasma and tumor interstitial fluid by microdialysis: application to pharmacokinetic studies. | LitMetric

HPLC-UV method for quantifying etoposide in plasma and tumor interstitial fluid by microdialysis: application to pharmacokinetic studies.

Biomed Chromatogr

Pharmaceutical Sciences Graduate Program, College of Pharmacy, Federal University of Rio Grande do Sul, Porto Alegre, Brazil; Centro Bioanalítico de Medicamentos, College of Pharmacy, Federal University of Rio Grande do Sul, Porto Alegre, Brazil.

Published: April 2015

A simple and sensitive bioanalytical method was developed and validated for determination of etoposide in plasma and microdialysis samples of Walker-256 tumor-bearing rats. A microdialysis probe was implanted in the center of a subcutaneous tumor and Ringer's solution was used as perfusion medium. Chromatographic separation was conducted on a Shimadzu CLC-C8 column using a mobile phase consisting of water-acetonitrile (70:30; v/v) adjusted to pH 4.0 ± 0.1 with formic acid at a gradient flow rate of 1.0-0.6 mL/min, an injection volume of 30 μL and UV detection at 210 nm. Microdialysate samples were analyzed without processing and plasma samples (100 μL) were spiked with phenytoin as internal standard (IS) (1 µg/mL) followed by extraction with tert-butyl methyl ether. The organic layer was evaporated and reconstituted with 100 μL of mobile phase before injection. The methods for plasma and microdialysate were linear in the ranges of 25-10,000 ng/mL and of 10-1500 ng/mL, respectively. All the validation parameters such as intra- and inter-day precision and accuracy and stability were within the limits established by international guidelines. The present method was successfully applied in the investigation of etoposide pharmacokinetics in rat plasma and microdialysate tumor samples following a single 15 mg/kg intravenous dose.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bmc.3308DOI Listing

Publication Analysis

Top Keywords

etoposide plasma
8
mobile phase
8
plasma microdialysate
8
plasma
5
hplc-uv method
4
method quantifying
4
quantifying etoposide
4
plasma tumor
4
tumor interstitial
4
interstitial fluid
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!