A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A microfabricated optofluidic ring resonator for sensitive, high-speed detection of volatile organic compounds. | LitMetric

Advances in microanalytical systems for multi-vapor determinations to date have been impeded by limitations associated with the microsensor technologies employed. Here we introduce a microfabricated optofluidic ring resonator (μOFRR) sensor that addresses many of these limitations. The μOFRR combines vapor sensing and fluidic transport functions in a monolithic microstructure comprising a hollow, vertical SiOx cylinder (250 μm i.d., 1.2 μm wall thickness; 85 μm height) with a central quasi-toroidal mode-confinement section, grown and partially released from a Si substrate. The device also integrates on-chip fluidic-interconnection and fiber-optic probe alignment features. High-Q whispering gallery modes generated with a tunable 1550 nm laser exhibit rapid, reversible shifts in resonant wavelength arising from polymer swelling and refractive index changes as vapors partition into the ~300 nm PDMS film lining the cylinder. Steady-state sensor responses varied in proportion to concentration over a 50-fold range for the five organic vapors tested, providing calculated detection limits as low as 0.5 ppm (v/v) (for m-xylene and ethylbenzene). In dynamic exposure tests, responses to 5 μL injected m-xylene vapor pulses were 710 ms wide and were only 18% broader than those from a reference flame-ionization detector and also varied linearly with injected mass; 180 pg was measured and the calculated detection limit was 49 pg without use of preconcentration or split injection, at a flow rate compatible with efficient chromatographic separations. Coupling of this μOFRR with a micromachined gas chromatographic separation column is demonstrated.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c4lc00739eDOI Listing

Publication Analysis

Top Keywords

microfabricated optofluidic
8
optofluidic ring
8
ring resonator
8
calculated detection
8
resonator sensitive
4
sensitive high-speed
4
high-speed detection
4
detection volatile
4
volatile organic
4
organic compounds
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!