Blade-plate fixation for distal femoral fractures: a case-control study.

Orthop Traumatol Surg Res

Service de chirurgie orthopédique et traumatologique, CHU de Nantes, 1, place Alexis-Ricordeau, 44000 Nantes, France.

Published: September 2014

Background: The blade-plate is the earliest of the contemporary internal fixation devices introduced for distal femoral fractures. The recent development of dedicated, fixation devices has considerably limited its use. The objective of this study was to evaluate outcomes after blade-plate fixation and after fixation using other devices.

Hypothesis: Outcomes after blade-plate fixation are similar to those after condylar screw-plate, distal femoral nail, or locking condylar plate fixation.

Material And Methods: We reviewed outcomes after 62 patients managed with blade-plate fixation and included in a multicentre retrospective study (n=57) or a multicentre prospective study (n=5) and we compared them to outcomes after fixation using condylar screw-plates (n=82), distal femoral nail (n=219), or locking condylar plates (n=301). The four groups were comparable for age, gender distribution, occupational status, prevalence of skin wounds, patient-related factors, type of accident, and type of fracture. The evaluation relied on the clinical International Knee Society (IKS) score and on radiographs.

Results: No significant differences existed across the four groups for operative time, blood transfusion use, complications, need for bone grafting, non-union rate, or IKS score values. The early surgical revision rate for removal of the fixation material was 4% with the blade-plate and 16% with the other three fixation devices (P=0.02). Post-operative fracture deformity was similar in the four groups with, however, a higher proportion of residual malalignment in the screw-fixation group. The final anatomic axis was 3.3±1.4° with the blade-plate versus 2.3±3.7° with the other three fixation devices. The blade-plate group had few patients with axial malalignment, and the degree of malalignment was limited to 3° of varus and 10° of valgus at the most, compared to 10° and 18° respectively, with the other three fixation devices.

Conclusion: Despite the now extremely limited use and teaching of blade-plate fixation, as well as the undeniable technical challenges raised by the implantation of this device, the blade-plate is a simple, strong, and inexpensive fixation method. It remains reliable for the fixation of distal femoral fractures. The disfavour into which the blade-plate is currently falling is not warranted.

Level Of Evidence: III, case-control study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.otsr.2014.06.006DOI Listing

Publication Analysis

Top Keywords

blade-plate fixation
20
distal femoral
20
fixation devices
16
fixation
14
femoral fractures
12
three fixation
12
blade-plate
11
fixation distal
8
case-control study
8
outcomes blade-plate
8

Similar Publications

Background Extracapsular hip fractures are routinely treated with fixation, and the majority heal without complication. The fixation fails in a minority of cases, typically either by 'cutting out' of the superior femoral head or through breakage of the metalwork following non-union. In such cases, if operative treatment is thought appropriate, there are two major treatment options: revision fixation of the fracture or joint replacement surgery.

View Article and Find Full Text PDF

Deep Learning for Automated Classification of Hip Hardware on Radiographs.

J Imaging Inform Med

September 2024

Department of Radiology, Stanford Medicine. 300 Pasteur Dr, Palo Alto, CA, 94304, USA.

Purpose: To develop a deep learning model for automated classification of orthopedic hardware on pelvic and hip radiographs, which can be clinically implemented to decrease radiologist workload and improve consistency among radiology reports.

Materials And Methods: Pelvic and hip radiographs from 4279 studies in 1073 patients were retrospectively obtained and reviewed by musculoskeletal radiologists. Two convolutional neural networks, EfficientNet-B4 and NFNet-F3, were trained to perform the image classification task into the following most represented categories: no hardware, total hip arthroplasty (THA), hemiarthroplasty, intramedullary nail, femoral neck cannulated screws, dynamic hip screw, lateral blade/plate, THA with additional femoral fixation, and post-infectious hip.

View Article and Find Full Text PDF

Recent studies report the overall incidence of distal femur fractures as 8.7/100,000/year. This incidence is expected to rise with high energy motor vehicle collisions and elderly osteoporotic fractures in native and prosthetic knees keep increasing.

View Article and Find Full Text PDF

Purpose: This study aimed to investigate the long-term outcomes of patients with a femoral neck fracture (FNF), treated with the Dynamic Locking Blade Plate (DLBP).

Methods: Retrospective analysis of prospectively collected data of a multicentre cohort of patients with FNFs was conducted, regarding the long-term incidence of revision surgery after DLBP. Implant failure was evaluated using Kaplan-Meier and Cox regression analysis.

View Article and Find Full Text PDF

[Is the 95°blade plate still important in the treatment of proximal femoral pseudarthrosis?].

Unfallchirurgie (Heidelb)

August 2024

Department of Trauma and Orthopedic Surgery, BG Unfallklinik Frankfurt, Friedberger Landstraße 430, 60389, Frankfurt am Main, Deutschland.

Due to demographic changes, fractures and subsequently delayed fracture healing as well as pseudarthrosis of the proximal femur are on the increase. In the acute fracture situation, a load-stable treatment with an intramedullary implant (cephalomedullary nail) is generally sought. To date, there is no uniform consensus on the optimal treatment for complicated cases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!