Contrasting electrogenerated chemiluminescence for a dissolved and surface-attached carbazole thiophene cyanoacrylate dye.

ACS Appl Mater Interfaces

Department of Chemistry and School of Energy Resources, University of Wyoming, Laramie, Wyoming 82071, United States.

Published: September 2014

The electrogenerated chemiluminescence (ECL) of a carbazole thiophene cyanoacrylate dye ((2-cyano-3-[5"'-(9-ethyl-9H-carbazol-3-yl)-3',3",3"',4-tetra-n-hexyl-[2,2',5',2",5",2"']-quarter-thiophenyl-5yl]acrylate) = MK-2) has been investigated in solution, where the maximum ECL wavelength occurs at 640 nm, and in a thin film on an ITO surface, where the ECL is substantially red-shifted to 730 nm. The ECL intensity for the solution annihilation reaction is relatively weak, whereas a much higher ECL intensity is measured with oxalate as a co-reactant. This result is attributed to the two Nernstian reversible oxidation waves of the thiophene moiety of MK-2, whereas the reduction is stabilized by the unblocked carbazole and cyanoacrylate groups.

Download full-text PDF

Source
http://dx.doi.org/10.1021/am503743vDOI Listing

Publication Analysis

Top Keywords

electrogenerated chemiluminescence
8
carbazole thiophene
8
thiophene cyanoacrylate
8
cyanoacrylate dye
8
ecl intensity
8
ecl
5
contrasting electrogenerated
4
chemiluminescence dissolved
4
dissolved surface-attached
4
surface-attached carbazole
4

Similar Publications

Probing Single-Particle Electrocatalytic Stability: Electrogenerated Chemiluminescence Imaging of Nanoparticle Array.

J Phys Chem Lett

December 2024

College of Engineering and Applied Sciences, State Key Laboratory of Analytical Chemistry for Life Science, and Jiangsu Key Laboratory of Artificial Functional Materials, Nanjing University, Nanjing 210093, China.

Understanding the stability of single nanoparticles is crucial for optimizing their performance in various applications, including catalysis. In this study, we employed electrochemiluminescence (ECL) imaging to investigate the temporal stability of individual Au and Pt nanoparticles within precisely engineered arrays. Our results reveal significant differences in the stability of Au and Pt NPs.

View Article and Find Full Text PDF

Coordination-Based Site-Specific Labeling Strategy for Electrogenerated Chemiluminescence Biosensing of Matrix Metalloproteinase 2.

Anal Chem

December 2024

Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, Shaanxi 710062, P. R. China.

Matrix metalloproteinase 2 (MMP-2) is an important biomarker for some diseases. Herein, one first-case coordination-based site-specific labeling strategy is proposed for electrogenerated chemiluminescence (ECL) biosensing of MMP-2 by employing an iridium(III) solvent complex as a signal reagent and a histidine (His)-containing peptide as a molecular recognition substrate. One ECL probe was prepared via coordination labeling of the His-containing peptide with one iridium(III) solvent complex ([(3-(2-pyridyl)benzoic acid)Ir(DMSO)Cl], Ir1-DMSO).

View Article and Find Full Text PDF

This study developed a dual-mode "on-off-on" sensor based on a bipyridine ruthenium metal-organic framework (Ru-MOF) and dual enzyme cleavage technology for the sensitive detection of the K-ras gene. The sensor combines electrogenerated chemiluminescence (ECL) and fluorescence (FL) detection modes, achieving high sensitivity and specificity in detecting the K-ras gene through catalytic hairpin assembly (CHA) and dual enzyme cleavage reactions. Experimental results showed that the detection limits for the K-ras gene were 0.

View Article and Find Full Text PDF

Microbubbles, inside-out microdroplets, act as extraordinary microreactors to facilitate thermodynamically unfavorable reactions in bulk solutions of water. We explored the formation of hydrogen peroxide (HO) and its sustained regeneration at the interface of water-gas microbubbles. For this purpose, the chemiluminescence of luminol was recorded by a digital camera to map the intensity of blue light emission over the time of about 20 min.

View Article and Find Full Text PDF

Analysis of single cancer cells is critical to obtain accurate patient diagnosis and prognosis. In this work, we report the selective dielectrophoretic capture and electrochemical analysis of single melanoma cells at an array of interlocked spiral bipolar electrodes (iBPEs). Following dielectrophoretic capture, individual melanoma cells are hydrodynamically transferred into picoliter-scale chambers for subsequent analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!