Objective. It is difficult to acquire a chest X-ray of a crying infant at maximum inspiration. A computer program was developed for technician training. Method. Video clips of 3 babies were used and the moment of deepest inspiration was determined in the single-frame view. 12 technicians simulated chest radiographs at normal video speed by pushing a button. The computer program stopped the video and calculated the period of time to the optimal instant for a chest X-ray. Demonstration software can be tested at website online. Every technician simulated 10 chest X-rays for each of the 3 video clips. The technicians then spent 40 minutes practicing performing chest X-rays at optimal inspiration. The test was repeated after 5, 20, and 40 minutes of practice. Results. 6 participants showed a significant improvement after exercises (collective 1). Deviation from the optimal instant for taking an X-ray at inspiration decreased from 0.39 to 0.22 s after 40 min of practice. 6 technicians showed no significant improvement (collective 2). Deviation decreased from a low starting value of 0.25 s to 0.21 s. Conclusion. The tested computer program improves the ability of radiology technicians to take a chest X-ray at optimal inspiration in a crying child.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4120922PMC
http://dx.doi.org/10.1155/2014/312846DOI Listing

Publication Analysis

Top Keywords

chest x-rays
12
chest x-ray
12
computer program
12
performing chest
8
radiology technicians
8
video clips
8
simulated chest
8
optimal instant
8
optimal inspiration
8
collective deviation
8

Similar Publications

CPR related injuries of the chest wall: direct and indirect fractures.

Eur J Trauma Emerg Surg

January 2025

Department of Trauma and Orthopedic Surgery, University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nürnberg (FAU), Erlangen, Germany.

Background: Rib and sternum fractures are common injuries associated with cardiopulmonary resuscitation (CPR). The fracture mechanism is either direct by application of force on sternum and anterior ribs or indirect by bending through compression of the thorax. The aim of this study was to determine morphologies of rib fractures after CPR and to reevaluate prior findings on fracture localisation, type and degree of dislocation.

View Article and Find Full Text PDF

Development of an image quality evaluation system for bedside chest X-ray images using scatter correction processing.

Radiol Phys Technol

January 2025

Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, 7-2-10 Higashi-ogu, Arakawa, Tokyo, 116-8551, Japan.

In plain radiography, scattered X-ray correction processing (Virtual Grid: VG) is used to estimate and correct scattered rays in images. We developed an objective evaluation system for bedside chest X-ray images using VG and investigated its usefulness. First, we trained the blind/referenceless image spatial quality evaluator (BRISQUE) on 200 images obtained by portable chest radiography.

View Article and Find Full Text PDF

Acute cardiovascular disorders are incriminated in up to 33% of maternal deaths, and the presence of sickle cell anemia (SCA) aggravates the risk of peripartum complications. Herein, we present a 24-year-old Caribbean woman with known SCA who developed a vaso-occlusive crisis at 36 weeks of gestation that required emergency Cesarean section. In the early postpartum period, she experienced fever with rapid onset of acute respiratory distress in the context of COVID-19 infection that required tracheal intubation and mechanical ventilatory support with broad-spectrum antibiotics and blood exchange transfusion.

View Article and Find Full Text PDF

The Role of Lung Ultrasound Scan in Different Heart Failure Scenarios: Current Applications and Lacks of Evidences.

Diagnostics (Basel)

December 2024

Cardiovascular Diseases Unit, Cardio Thoracic and Vascular Department, Le Scotte Hospital, University of Siena, 53100 Siena, Italy.

Pulmonary congestion is a critical factor influencing the clinical presentation, therapeutic decisions, and outcomes of heart failure (HF) patients. Lung ultrasound (LUS) offers a simple, rapid, and accurate method for assessing pulmonary congestion, surpassing the diagnostic capabilities of traditional clinical evaluation and chest radiography. Due to the wide availability of ultrasound equipment, congestion can be evaluated in multiple settings, ranging from emergency departments to intensive care units, including outpatient settings.

View Article and Find Full Text PDF

Dynamic Digital Radiography (DDR) in the Diagnosis of a Diaphragm Dysfunction.

Diagnostics (Basel)

December 2024

Postgraduation School in Radiodiagnostics, Università degli Studi di Milano, Via Festa del Perdono 7, 20122 Milan, Italy.

Dynamic digital radiography (DDR) is a recent imaging technique that allows for real-time visualization of thoracic and pulmonary movement in synchronization with the breathing cycle, providing useful clinical information. A 46-year-old male, a former smoker, was evaluated for unexplained dyspnea and reduced exercise tolerance. His medical history included a SARS-CoV-2 infection in 2021.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!