A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Analytical performances of SPAPLUS® turbidimeter for the dosage of immunoglobulins and beta-2 microglobulin in serum]. | LitMetric

We evaluated the analytical performances of the SPAPLUS(®) immunoturbidimeter assays manufactured by The Binding Site(®) for the quantification of thirteen immunological parameters in serum: IgG, IgA, IgM and IgD immunoglobulins, IgG subclasses (1 to 4), IgA subclasses (1 and 2), beta-2 microglobulin, free light chains kappa and lambda. The within-day precision (repeatability) and the between-day precision (reproducibility) were obtained for two or three concentration levels depending of the parameter and were below the recommendations of the manufacturer, except for the repeatability of IgG1 (at a level of concentration of 6.7 g/L). An agreement above 90% (with Bland and Altman analysis) was observed between the results obtained with SPAPLUS(®) and those obtained with the nephelometer IMMAGE(®) 800 or radial immunodiffusion. The evaluation confirmed the linearity of the assays and the absence of contamination for all the parameters tested. We also assessed the practicability of the SPAPLUS(®) in terms of maintenance, frequency of calibration and cadence tests. The SPAPLUS(®) immunoturbidimeter displays good analytical performances for the immunological parameters evaluated in the present work.

Download full-text PDF

Source
http://dx.doi.org/10.1684/abc.2014.0974DOI Listing

Publication Analysis

Top Keywords

performances spaplus®
8
beta-2 microglobulin
8
analytical performances
8
spaplus® immunoturbidimeter
8
immunological parameters
8
spaplus®
5
[analytical performances
4
spaplus® turbidimeter
4
turbidimeter dosage
4
dosage immunoglobulins
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!