Optimization of dual-energy subtraction chest radiography by use of a direct-conversion flat-panel detector system.

Radiol Phys Technol

Division of Radiology, Department of Medical Technology, Osaka University Hospital, 2-15, Yamadaoka, Suita, Osaka, 565-0871, Japan,

Published: January 2015

We aimed to optimize the exposure conditions in the acquisition of soft-tissue images using dual-energy subtraction chest radiography with a direct-conversion flat-panel detector system. Two separate chest images were acquired at high- and low-energy exposures with standard or thick chest phantoms. The high-energy exposure was fixed at 120 kVp with the use of an auto-exposure control technique. For the low-energy exposure, the tube voltages and entrance surface doses ranged 40-80 kVp and 20-100 % of the dose required for high-energy exposure, respectively. Further, a repetitive processing algorithm was used for reduction of the image noise generated by the subtraction process. Seven radiology technicians ranked soft-tissue images, and these results were analyzed using the normalized-rank method. Images acquired at 60 kVp were of acceptable quality regardless of the entrance surface dose and phantom size. Using a repetitive processing algorithm, the minimum acceptable doses were reduced from 75 to 40 % for the standard phantom and to 50 % for the thick phantom. We determined that the optimum low-energy exposure was 60 kVp at 50 % of the dose required for the high-energy exposure. This allowed the simultaneous acquisition of standard radiographs and soft-tissue images at 1.5 times the dose required for a standard radiograph, which is significantly lower than the values reported previously.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12194-014-0285-yDOI Listing

Publication Analysis

Top Keywords

soft-tissue images
12
high-energy exposure
12
dose required
12
dual-energy subtraction
8
subtraction chest
8
chest radiography
8
radiography direct-conversion
8
direct-conversion flat-panel
8
flat-panel detector
8
detector system
8

Similar Publications

CT is the gold standard for evaluating orbital trauma, providing rapid and detailed imaging of bony structures, soft tissue, and the globe. This is crucial in assessing orbital trauma due to its potential to cause significant impairment of ocular function. This case report presents a 35-year-old male who was admitted to the emergency department with a complicated left orbital blow-out fracture following blunt facial trauma.

View Article and Find Full Text PDF

Hepatic mesenchymal hamartoma (HMH) is an uncommon, benign liver tumor predominantly affecting children under three years of age. It is characterized histologically by disorganized mesenchymal stroma, abnormal bile ducts, blood vessels, and hepatocytes. HMH can present as a large cystic mass, a solid mass, or a combination of both.

View Article and Find Full Text PDF

Yaks are a domesticated species utilized for meat, fiber, and transportation in many countries. In the United States, yak meat is growing in popularity due to its classification as a "healthy" meat. Penetrating captive bolt (PCB) is an approved method of preslaughter stunning and euthanasia for cattle.

View Article and Find Full Text PDF

The present study was a retrospective single-center study. A total of 81 patients diagnosed with metastatic soft tissue sarcoma were included who received pazopanib therapy. Clinical data, including age at diagnosis, histological subtype, treatments received before pazopanib, number of metastatic sites at the time of initiation of treatment, progression-free survival and overall survival time under pazopanib treatment, side effects and response evaluation in follow-up imaging after initiation of pazopanib therapy, were recorded.

View Article and Find Full Text PDF

Background: A 63-year-old Black woman presented with progressive exertional dyspnea and chronic lower back pain. The course and findings in her case are instructive.

Case Report: Family history was notable for cardiac deaths.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!