A vapour-permeable film dressing used on superficial wounds.

Br J Nurs

Wound Care Specialist, Wound Care and Diabetic Foot Centre, Zottegem, Belgium.

Published: August 2014

Films are an extremely versatile dressing type that can be effectively used in the treatment of many superficial wounds, such as skin grafts, surgical wounds and superficial burns; they provide an optimal moist environment to promote healing, act as a barrier to bacteria, and afford protection from urine and faecal contamination. Unfortunately, many film dressings are difficult to handle and use traditional adhesives, which can cause trauma to the wound and surrounding skin, as well as increased wound pain at dressing removal. Mepitel® Film is a new, easy-to-use wound dressing designed with Safetac® technology that helps to minimise dressing-related trauma and pain and assist undisturbed wound healing. This article presents case studies that examine Mepitel Film's use on a variety of wounds, and reviews the findings of research that was undertaken to evaluate the benefits of using this recently developed dressing.

Download full-text PDF

Source
http://dx.doi.org/10.12968/bjon.2014.23.Sup15.s36DOI Listing

Publication Analysis

Top Keywords

superficial wounds
8
dressing
5
vapour-permeable film
4
film dressing
4
dressing superficial
4
wounds
4
wounds films
4
films extremely
4
extremely versatile
4
versatile dressing
4

Similar Publications

Keloids are characterized by excessive growth of fibrous tissue resulting from abnormal wound-healing processes. They may lead to functional impairments, aesthetic deformities, pruritus, and a decreased quality of life. Various therapies, including intralesional corticosteroid injections, cryotherapy, laser therapy, surgical excision, and radiotherapy, have been used to manage keloids, but the recurrence rates remain high.

View Article and Find Full Text PDF

Biologically-oriented alveolar ridge preservation to correct bone dehiscence at immediate implant placement.

Clin Adv Periodontics

January 2025

Operative Unit of Dentistry, Azienda Unità Sanitaria Locale, Ferrara, Italy.

Background: The purpose of the present case study is to describe the application of a modification of the Biologically-oriented Alveolar Ridge Preservation (BARP) principles in cases of peri-implant bone dehiscence (PIBD) due to a compromised alveolus at immediate implant placement (IIP).

Methods: The technique is based on the stratification of three layers: a deep layer with a collagen sponge (CS) in the apical part of the alveolus (where the buccal bone plate was still present) to support the blood clot; a graft layer to correct the PIBD; and a superficial collagen layer to cover the graft thus providing space and enhancing clot/graft stability. Healing was obtained by primary closure.

View Article and Find Full Text PDF

Background: Bicondylar tibial plateau fractures are often associated with significant soft tissue compromise making operative treatment challenging. Dual plating through a two-incision approach following temporary external fixation has been shown to improve complication rates although deep infection rates remain high.The objective was to evaluate early outcomes following a novel technique of percutaneous application of the medial plate superficial to the pes anserinus tendons.

View Article and Find Full Text PDF

Microneedles as transdermal drug delivery system for enhancing skin disease treatment.

Acta Pharm Sin B

December 2024

State Key Laboratory of Advanced Medical Materials and Devices, Tianjin Key Laboratory of Biomedical Materials, Key Laboratory of Biomaterials and Nanotechnology for Cancer Immunotherapy, Institute of Biomedical Engineering, Tianjin Institutes of Health Science, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China.

Microneedles (MNs) serve as a revolutionary paradigm in transdermal drug delivery, heralding a viable resolution to the formidable barriers presented by the cutaneous interface. This review examines MNs as an advanced approach to enhancing dermatological pathology management. It explores the complex dermis structure and highlights the limitations of traditional transdermal methods, emphasizing MNs' advantage in bypassing the stratum corneum to deliver drugs directly to the subdermal matrix.

View Article and Find Full Text PDF

Cardiac implantable electronic devices (CIEDs), including pacemakers, implantable cardiac defibrillators (ICD), and cardiac resynchronization therapy (CRT) devices, regulate heart rate and rhythm in patients with cardiac conditions. With an aging population, CIED-related complications, especially pacemaker pocket infections, are rising. Risk factors include frailty, older age, and superficial device fixation, while risk mitigation involves larger pocket sizes, submuscular fixation, and absorbable antibacterial envelopes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!