Purpose Of The Study: An analysis of long-term results of the all-polyethylene tibial component in Walter-Motorlet cemented condylar knee arthroplasty, with a standard tibial plateau (STP) of our own design.
Material And Methods: A total of 49 patients underwent knee replacement; of them, 35 (71.4%) with 38 Walter-Motorlet implants using the STP were evaluated. The average age at the time of evaluation was 87.3 years. The follow-up ranged from 18 to 27 years (average, 24.6 years). Mechanical properties of the STP were tested by experimental measurements and in a photoelasticimetric study. The clinical results were evaluated according to the EULAR Knee Assessment Chart (EKACH). Twenty-four patients (26 knees; 49%) had osteoarthritis (OA) and 11 (12 knees; 23%) had rheumatoid arthritis (RA). Of the 14 (28.6%) patients not included in evaluation, seven (14.3%), with seven knees, required revision arthroplasty and seven (14.3%), with 10 knees, were lost to follow-up.
Results: Of the 38 implants evaluated by the EKACH at an average of 24.6 years, subjectively, 14 (36.8%) knees were free from pain and 14 (36.8%) were mildly painful. The remaining 10 (26.4%) joints were acutely painful on walking up or down the hill. In 14 (36.8%) cases the patients experienced their knees as stable. Light domestic chores were routinely performed by 17 patients (10 OA and 7 RA; 48.6%). One (2.9%) OA patient had a full-time job, and nine (25.7%) patients were socially independent. The functional outcome was significantly related to the patient's age at the time of evaluation. Complications included STP aseptic loosening in five (13.1%) and late infection in two (5.2%) knees. Radiography showed translucent zones below an all-polyethylene component in 14 (36.8%) knees. DISCUSSION The five cases of aseptic loosening may have been due to insufficient hardness of a U-shaped polyethylene component and long-term stress at the bone-implant interface. In the majority of knees the anterior cruciate ligament was defective or missing completely. Maintenance of the posterior cruciate ligament facilitates absorption of the greater part of forces at the cement-bone interface, as also reported by other authors. The high incidence of complications associated with patellar components, as described in the literature of the late 1970s and the early 1980s, led us to avoid the primary use of a patellar implant.
Conclusions: Our evaluation showed that, in 73% of the cases, the all-polyethylene tibial component was a suitable and inexpensive implant with very good or good long-term results on average at 24.6 years of follow-up. Since the quality of currently produced polyethylene is high, we recommend the use of all-polyethylene tibial components in all indicated cases.
Download full-text PDF |
Source |
---|
J Exp Orthop
January 2025
Department of Orthopaedic Surgery, Faculty of Medicine The University of Tokyo Tokyo Japan.
Purpose: To clarify the influence of biomechanics on post-operative clinical outcomes in bicruciate-retaining total knee arthroplasty (BCR-TKA).
Methods: Severe medial osteoarthritis who underwent BCR-TKA were examined. Each patient was asked to perform a squat (weight-bearing [WB]) and active assisted knee flexion (non-WB [NWB]) under single fluoroscopy surveillance.
Cureus
December 2024
Department of Health Sciences, Graduate School of Biomedical Sciences, Nagasaki University, Nagasaki, JPN.
Purpose The infrapatellar fat pad (IFP) has the lowest pain threshold among all knee joint components and causes anterior knee pain after knee arthroplasty. It has been reported that selective muscle atrophy of the vastus medialis (VM) and fibrosis of the IFP may develop following knee joint surgery. Ultrasound enables visualization of IFP deformation (A1) from within the joint to the proximal area in response to muscle contraction, and this may be helpful in developing preventive and therapeutic strategies for IFP fibrosis.
View Article and Find Full Text PDFJ Arthroplasty
January 2025
Georgetown University School of Medicine, MedStar Georgetown University Hospital, Washington, D.C, USA. Electronic address:
Introduction: As the number of revision total knee arthroplasties (rTKA) continues to rise, there is increasing interest in the use of contemporary rotating hinge prostheses. These devices often incorporate porous cones to fill bone defects and enhance long-term fixation. This study evaluated the clinical and functional outcomes and survivorship in rTKA patients utilizing a rotating hinge prosthesis with flexible titanium (FT) cones, porous tantalum (PT) cones, or no cones.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea.
: Patient-specific instrumentation (PSI) in total knee arthroplasty (TKA) uses preoperative three-dimensional imaging to create cutting blocks tailored to patient anatomy. However, there is debate regarding the additional benefits of PSI in terms of improved alignment or functional outcomes compared to using conventional instruments. Although PSI design has undergone continuous development, the improvements have not been incorporated.
View Article and Find Full Text PDFClin Orthop Relat Res
January 2025
Department of Rehabilitation, Radboud University Medical Center, Nijmegen, the Netherlands.
Background: Many patients with a lower limb socket-suspended prothesis experience socket-related problems, such as pain, chronic skin conditions, and mechanical problems, and as a result, health-related quality of life (HRQoL) is often negatively affected. A bone-anchored prosthesis can overcome these problems and improve HRQoL, but these prostheses have potential downsides as well. A valid and reliable tool to assess potential candidates for surgery concerning a favorable risk-benefit ratio between potential complications related to bone-anchored prostheses and improvements in HRQoL is not available yet.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!