Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: The purpose of this study was to assess the bond strength of a restorative material to bleached dentin, pretreated with Er:YAG laser.
Background Data: Laser irradiation for dental surface treatment may increase the bond strength of restorative material to tooth surface. There are no reports of using Er:YAG laser on dentin bleached with 35% hydrogen peroxide.
Methods: Forty maxillary canines were sectioned, resulting in 80 fragments (5×5 mm) of intracoronary dentin that were divided into eight groups (n=10) according to the dental bleaching (present or not), surface conditioning (with or without laser) and the post-bleaching time to perform restoration (immediately or 7 days). The bleached specimens received two applications of 38% hydrogen peroxide. Er:YAG laser was applied for 20 sec with 400 mJ/15 Hz. Restorative procedure was performed using phosphoric acid, an adhesive system, and resin using a split Teflon matrix. The specimens were submitted to shear bond strength test and the data (MPa) were analyzed by ANOVA and Tukey's test (α=0.05).
Results: There were significant differences among the three factors (p<0.05). The highest values were obtained for unbleached specimens compared with bleached, for those treated with laser compared with those only conditioned with acid, and for those restored after 7 days compared with those having immediate restoration. In the interaction of factors, the bleached specimens treated with laser and restored immediately were statistically similar (p>0.05) to those bleached and restored after 7 days.
Conclusions: Er:YAG laser can restore the bond strength of the dentin/restorative material interface even if the restoration is performed immediately after bleaching.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1089/pho.2014.3721 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!