A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Catheter displacement prior to the delivery of high-dose-rate brachytherapy in the treatment of prostate cancer patients. | LitMetric

Purpose: The purpose of this work was to report measured catheter displacement prior to the delivery of high-dose-rate brachytherapy (HDR) in the treatment of prostate cancer.

Material And Methods: Data from 30 prostate cancer patients treated with HDR brachytherapy were analyzed retrospectively. Eighteen transperineal hollow catheters were inserted under transrectal ultrasound guidance. Gold marker seeds were also placed transperineally into the base and apex of the prostate gland. Five treatment fractions of 7.5 Gy each were administered over 3 days. The patient underwent CT scanning prior to each treatment fraction. Catheter displacement was measured from the pre-treatment CT dataset reconstructed at 1.25 mm slice thickness.

Results: Most of catheters were displaced in the caudal direction. Variations of 18 catheters for each patient were small (standard deviations < 1 mm for all but one patient). Mean displacements relative to the apex marker were 6 ± 4 mm, 12 ± 6 mm, 12 ± 6 mm, 12 ± 6 mm, and 12 ± 6 mm from plan to 1(st), 2(nd), 3(rd), 4(th), and 5(th) fractions, respectively.

Conclusions: Our results indicate that catheter positions must be confirmed and if required, adjusted, prior to every treatment fraction for the precise treatment delivery of HDR brachytherapy, and to potentially reduce over-dosage to the bulbo-membranous urethra.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4105648PMC
http://dx.doi.org/10.5114/jcb.2014.43619DOI Listing

Publication Analysis

Top Keywords

catheter displacement
12
displacement prior
8
prior delivery
8
delivery high-dose-rate
8
high-dose-rate brachytherapy
8
treatment prostate
8
prostate cancer
8
cancer patients
8
hdr brachytherapy
8
prior treatment
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!