A new approach for dose calculation in targeted radionuclide therapy (TRT) based on collapsed cone superposition: validation with (90)Y.

Phys Med Biol

APHP-Service de médecine nucléaire, Hôpital Beaujon, F-92110 Clichy, France. INSERM U1149, Clichy, France.

Published: September 2014

To speed-up the absorbed dose (AD) computation while accounting for tissue heterogeneities, a Collapsed Cone (CC) superposition algorithm was developed and validated for (90)Y. The superposition was implemented with an Energy Deposition Kernel scaled with the radiological distance, along with CC acceleration. The validation relative to Monte Carlo simulations was performed on 6 phantoms involving soft tissue, lung and bone, a radioembolisation treatment and a simulated bone metastasis treatment. As a figure of merit, the relative AD difference (ΔAD) in low gradient regions (LGR), distance to agreement (DTA) in high gradient regions and the γ(1%,1 mm) criterion were used for the phantoms. Mean organ doses and γ(3%,3 mm) were used for the patient data. For the semi-infinite sources, ΔAD in LGR was below 1%. DTA was below 0.6 mm. All profiles verified the γ(1%,1 mm) criterion. For both clinical cases, mean doses differed by less than 1% for the considered organs and all profiles verified the γ(3%,3 mm). The calculation time was below 4 min on a single processor for CC superposition and 40 h on a 40 nodes cluster for MCNP (10(8) histories). Our results show that the CC superposition is a very promising alternative to MC for (90)Y dosimetry, while significantly reducing computation time.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/59/17/4769DOI Listing

Publication Analysis

Top Keywords

collapsed cone
8
cone superposition
8
gradient regions
8
γ1%1 mm criterion
8
profiles verified
8
superposition
5
approach dose
4
dose calculation
4
calculation targeted
4
targeted radionuclide
4

Similar Publications

Background: Direct mechanical ventricular actuation (DMVA) with the Anstadt cup is effective for non-blood-contacting biventricular support. Pneumatic regulation of a silicone device augments ventricular pump function. Vacuum attachment facilitates diastolic augmentation critical for biventricular support.

View Article and Find Full Text PDF

Aim: To study the dosimetric behavior of dose computational algorithms in inhomogeneous medium using CMS XiO and MONACO treatment planning system (TPS) for 4 megavoltage (MV), 6 MV and 15 MV photon beam energies.

Material And Methods: Styrofoam blocks of thickness 1.90 cm, 3.

View Article and Find Full Text PDF

Optogenetic Control of Receptor-mediated Growth Cone Dynamics in Neurons.

Mol Biol Cell

December 2024

Department of Neuroscience, Jefferson Center for Synaptic Biology, Vickie and Jack Farber Institute for Neuroscience, Sydney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA 19107.

Development of neuronal connections is spatially and temporally controlled by extracellular cues which often activate their cognate cell surface receptors and elicit localized cellular responses. Here, we demonstrate the use of an optogenetic tool to activate receptor signaling locally to induce actin-mediated growth cone remodeling in neurons. Based on the light-induced interaction of light between Cryptochrome 2 (CRY2) and CIB1, we generated a bicistronic vector to co-expresses CRY2 fused to the intracellular domain of a guidance receptor and a membrane-anchored CIB1.

View Article and Find Full Text PDF
Article Synopsis
  • Drilling wells in unconsolidated formations aims to improve water extraction efficiency but faces challenges like potential well collapse when targeting greater depths and larger diameters.
  • Experimental investigations explore the effectiveness of various drilling fluids and additives, including bentonite, PAC, Xanthan Gum, calcium carbonate, and aluminum chloride, to enhance wellbore stability in aquifers.
  • Results show that calcium carbonate effectively forms filter cakes that improve stability, while certain formulations like 2% aluminum chloride lead to thicker, but more permeable filter cakes, impacting filtration losses and well performance.
View Article and Find Full Text PDF

Background: Different dose calculation methods vary in accuracy and speed. While most methods sacrifice precision for efficiency Monte Carlo (MC) simulation offers high accuracy but slower calculation. ISOgray treatment planning system (TPS) uses Clarkson, collapsed cone convolution (CCC), and fast Fourier transform (FFT) algorithms for dose distribution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!