A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Applied research on the physical model for calculating optical constant of metal oxide films]. | LitMetric

In the present paper, two metal oxide films of HfO2 and Ta2 O5 were prepared by ion beam sputtering technology. Through measuring ellipsometric parameters of HfO2 and Ta2O5 films, their optical constants can be inversion-calculated by nonlinear least squares techniques. In the fitting process, eight experiment groups were arranged by the orthogonal table L8 (2(7)). After selecting Cauchy model, the largest influencing factor for fitting optical constant of HfO2 is surface layer model and the largest influencing factor for fitting optical constant of Ta2 O5 is refractive index gradient model. The impact of different physical model on MSE and the order for selecting model in the fitting process are determined. According to the selecting model and the determined fitting order, optical constants of the two metal oxide films were inversion-calculated with adding weak absorption model, and the obtained MSE can descend 79% and 39% according to the initial value. The results indicated that the selecting model possesses definite physical significance in the fitting process. The obtained method can be applied in inversion-calculating many metal oxide films with weak absorption. It has wide application value. At 500 nm, the refractive index gradient of Ta2O5 films is greater than HfO2 films, while the extinction coefficient of HfO2 films is greater than Ta2O5. It was shown that Hf metal is easier to form stable oxide than Ta metal. And the absorption of HfO2 films is larger than Ta2O5 films.

Download full-text PDF

Source

Publication Analysis

Top Keywords

metal oxide
16
optical constant
12
oxide films
12
ta2o5 films
12
fitting process
12
selecting model
12
hfo2 films
12
model
9
films
9
physical model
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!