Abstract During the past decade substantial development of computer-aided tracking technology has occurred. Therefore, we aimed to provide calibration equations to allow the interchangeability of different tracking technologies used in soccer. Eighty-two highly trained soccer players (U14-U17) were monitored during training and one match. Player activity was collected simultaneously with a semi-automatic multiple-camera (Prozone), local position measurement (LPM) technology (Inmotio) and two global positioning systems (GPSports and VX). Data were analysed with respect to three different field dimensions (small, <30 m to full-pitch, match). Variables provided by the systems were compared, and calibration equations (linear regression models) between each system were calculated for each field dimension. Most metrics differed between the 4 systems with the magnitude of the differences dependant on both pitch size and the variable of interest. Trivial-to-small between-system differences in total distance were noted. However, high-intensity running distance (>14.4 km · h) was slightly-to-moderately greater when tracked with Prozone, and accelerations, small-to-very largely greater with LPM. For most of the equations, the typical error of the estimate was of a moderate magnitude. Interchangeability of the different tracking systems is possible with the provided equations, but care is required given their moderate typical error of the estimate.

Download full-text PDF

Source
http://dx.doi.org/10.1080/02640414.2014.942687DOI Listing

Publication Analysis

Top Keywords

tracking systems
8
local position
8
position measurement
8
interchangeability tracking
8
typical error
8
error estimate
8
integrating tracking
4
systems football
4
football multiple
4
multiple camera
4

Similar Publications

Solu: a cloud platform for real-time genomic pathogen surveillance.

BMC Bioinformatics

January 2025

Solu Healthcare Oy, Kalevankatu 31 A 13, 00100, Helsinki, Finland.

Background: Genomic surveillance is extensively used for tracking public health outbreaks and healthcare-associated pathogens. Despite advancements in bioinformatics pipelines, there are still significant challenges in terms of infrastructure, expertise, and security when it comes to continuous surveillance. The existing pipelines often require the user to set up and manage their own infrastructure and are not designed for continuous surveillance that demands integration of new and regularly generated sequencing data with previous analyses.

View Article and Find Full Text PDF

Automated Incidental Findings Notification Through the Electronic Health Record Utilizing Dictation Macros.

J Imaging Inform Med

January 2025

University Hospitals Cleveland Medical Center, Case Western Reserve University, 11100 Euclid Avenue, BSH 5056, Cleveland, OH, 44106, USA.

The objective of this study is to implement an actionable incidental findings (AIFs) communication workflow integrated into the electronic health record (EHR) using dictation macros to improve the quality of radiology reports and facilitate delivery of findings to clinicians. The workflow was implemented across an academic multi-hospital health system and used by over 100 radiologists from 12 divisions. Standardized macros were created for different organ systems including the thyroid, lungs, liver, pancreas, spleen, kidney, female reproductive, and others, designed based on the ACR Novel Quality Measure Set.

View Article and Find Full Text PDF

Microscopic augmented reality calibration with contactless line-structured light registration for surgical navigation.

Med Biol Eng Comput

January 2025

Mechanical Engineering Department, Tianjin University, No. 135, Yaguan Road, Haihe Education Park, Jinnan District, Tianjin City, 300350, China.

The use of AR technology in image-guided neurosurgery enables visualization of lesions that are concealed deep within the brain. Accurate AR registration is required to precisely match virtual lesions with anatomical structures displayed under a microscope. The purpose of this work was to develop a real-time augmented surgical navigation system using contactless line-structured light registration, microscope calibration, and visible optical tracking.

View Article and Find Full Text PDF

How are arbitrary sequences of verbal information retained and manipulated in working memory? Increasing evidence suggests that serial order in verbal WM is spatially coded and that spatial attention is involved in access and retrieval. Based on the idea that brain areas controlling spatial attention are also involved in oculomotor control, we used eye tracking to reveal how the spatial structure of serial order information is accessed in verbal working memory. In two experiments, participants memorized a sequence of auditory words in the correct order.

View Article and Find Full Text PDF

Antimicrobial resistance (AMR), arising from decades of imprudent anthropogenic use of antimicrobials in healthcare and agriculture, is considered one of the greatest One Health crises facing healthcare globally. Antimicrobial pollutants released from human-associated sources are intensifying resistance evolution in the environment. Due to various ecological factors, wildlife interact with these polluted ecosystems, acquiring resistant bacteria and genes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!