Objective: Surgical use of robots has evolved over the last 10 years. However, the academic experience with robotic lung segmentectomy remains limited. We aimed to analyze our lung segmentectomy experience with robot-assisted thoracoscopic surgery.
Methods: Prospectively recorded clinical data of 21 patients who underwent robotic lung anatomic segmentectomy with robot-assisted thoracoscopic surgery were retrospectively reviewed. All cases were done using the da Vinci System. A three incision portal technique with a 3 cm utility incision in the posterior 10(th) to 11(th) intercostal space was performed. Individual dissection, ligation and division of the hilar structures were performed. Systematic mediastinal lymph node dissection or sampling was performed in 15 patients either with primary or secondary metastatic cancers.
Results: Fifteen patients (75%) were operated on for malignant lung diseases. Conversion to open surgery was not necessary. Postoperative complications occurred in four patients. Mean console robotic operating time was 84±26 (range, 40-150) minutes. Mean duration of chest tube drainage and mean postoperative hospital stay were 3±2.1 (range, 1-10) and 4±1.4 (range, 2-7) days respectively. The mean number of mediastinal stations and number of dissected lymph nodes were 4.2 and 14.3 (range, 2-21) from mediastinal and 8.1 (range, 2-19) nodes from hilar and interlobar stations respectively.
Conclusions: Robot-assisted thoracoscopic segmentectomy for malignant and benign lesions appears to be practical, safe, and associated with few complications and short postoperative hospitalization. Lymph node removal also appears oncologically acceptable for early lung cancer patients. Benefits in terms of postoperative pain, respiratory function, and quality of life needs a comparative, prospective series particularly with video-assisted thoracoscopic surgery.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4120181 | PMC |
http://dx.doi.org/10.3978/j.issn.2072-1439.2014.06.40 | DOI Listing |
J Vasc Interv Radiol
January 2025
Gustave Roussy (GR), Département d'Anesthésie Chirurgie et Interventionnelle (DACI), Service d'Imagerie Thérapeutique, Villejuif France; Centre d'Investigation Clinique BIOTHERIS, INSERM CIC1428, Villejuif, France; Radiologie Interventionnelle, Gustave Roussy, Villejuif, France; Laboratoire de Recherche Translationnelle en Immunothérapie (LRTI), INSERM U1015, Villejuif, France; Faculté de Médecine, Paris-Saclay Université, F-94276 Le Kremlin Bicêtre, France.
Purpose: To evaluate the feasibility and accuracy of a robotic device used clinically in soft tissues (abdomen and lung), modified in design and workflow, to perform needle insertion in percutaneous bone procedures.
Methods: The primary objective was safety (severe complications) of robotic-assisted insertion in this new application. Secondary objectives were feasibility (placement technical success), performance (acceptable insertions rate), accuracy (lateral deviation), number of intermediate CT-scans and tolerance (minor/moderate complications).
Surg Pract Sci
September 2024
Department of Thoracic Oncology, Moffitt Cancer Center, Tampa, FL, USA.
Background: Marital status has been shown to have protective effects for married patients with various cancers. We sought to determine effects of marital status on perioperative outcomes after robotic-assisted pulmonary lobectomy (RAPL).
Methods: We retrospectively analyzed 709 consecutive patients who underwent RAPL between 2010 and 2022 by one surgeon.
Quant Imaging Med Surg
January 2025
Department of Diagnostic Radiology, First Medical Center of the Chinese PLA General Hospital, Beijing, China.
Background: Traditional freehand puncture relies on non-real-time computed tomography (CT) images, which significantly affects the accuracy of puncturing targets in the lower lung lobes with respiratory motion. This study aims to assess the safety and feasibility of a teleoperated robotic system and low-dose CT for the accurate real-time puncture of targets in the lungs of live pigs during breathing under fluoroscopic guidance.
Methods: Two puncture methods were analyzed: freehand and robot-assisted.
Thorax
January 2025
Division of Pulmonary, Allergy, and Sleep Medicine, Mayo Clinic Florida, Jacksonville, Florida, USA.
Background: Sampling of peripheral pulmonary lesions (PPLs) abutting the pleura carries a higher risk of pneumothorax and complications. Although typically performed with image-guided transthoracic biopsy, the advent of shape-sensing robotic-assisted bronchoscopy (ssRAB) provides an alternative diagnostic procedure for this subtype of lesions.
Methods: A retrospective study on PPL attached to the peripheral pleura (PP), comprising costal and diaphragmatic pleura, mediastinal pleura (MP), and fissural pleura (FP) sampled by ssRAB, from January 2020 to December 2023.
J Thorac Dis
December 2024
Shanghai Lung Cancer Center, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Background: Robot-assisted thoracic surgery has been shown to have several advantages over conventional surgery. As mobile communication technology and surgical robotic devices in China continue to progress rapidly, the conditions for performing remote surgery have been optimized. Consequently, informatized and remote advanced medical cooperation is becoming a new direction for supporting the medical development of border regions and promoting the equitable distribution of medical resources in China.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!