Study Design: This study compares the accuracy rates of lumbar percutaneous pedicle screw placement (PPSP) using either 2-dimensional (2-D) fluoroscopic guidance or 3-dimensional (3-D) stereotactic navigation in the setting of minimally invasive spine surgery (MISS). This represents the largest single-operator study of its kind and first comprehensive review of 3-D stereotactic navigation in the setting of MISS.

Objective: To examine differences in accuracy of lumbar pedicle screw placement using 2-D fluoroscopic navigation and 3-D stereotaxis in the setting of MISS.

Summary Of Background Data: Surgeons increasingly rely upon advanced image guidance systems to guide minimally invasive PPSP. Three-dimensional stereotactic navigation with intraoperative computed tomography offers well-documented benefit in open surgical approaches. However, the utility of 3-D stereotaxis in the setting of MISS remains incompletely explored by few studies with limited patient numbers.

Materials And Methods: A total of 599 consecutive patients underwent minimally invasive lumbar PPSP aided by 3-D stereotactic navigation. Postoperative imaging and medical records were analyzed for patient demographics, incidence and degree of pedicle breach, and other surgical complications. A total of 2132 screw were reviewed and compared with a meta-analysis created from published data regarding the placement of 4248 fluoroscopically navigated pedicle screws in the setting of MISS.

Results: In the 3-D navigation group, a total of 7 pedicle breaches occurred in 6 patients, corresponding to a per-person breach rate of 1.15% (6/518) and a per-screw breach rate of 0.33% (7/2132). Meta-analysis comprised of data from 10 independent studies showed overall breach risk of 13.1% when 2-D fluoroscopic navigation was utilized in MISS. This translates to a 99% decrease in odds of breach in the 3-D navigation technique versus the traditional 2-D-guided technique, with an odds ratio of 0.01, (95% confidence interval, 0.01-0.03), P<0.001.

Conclusions: Three-dimensional stereotactic navigation based upon intraoperative computed tomography imaging offers markedly improved accuracy of percutaneous lumbar pedicle screw placement when used in the setting of MISS.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BSD.0000000000000152DOI Listing

Publication Analysis

Top Keywords

minimally invasive
16
stereotactic navigation
16
screw placement
12
2-d fluoroscopic
12
3-d stereotactic
12
image guidance
8
pedicle screw
8
navigation
8
navigation setting
8
fluoroscopic navigation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!