Diagnostic accuracy of abdominal ultrasound in the screening of esophageal varices in patients with cirrhosis.

Eur J Gastroenterol Hepatol

aDigestive Diseases Service bInternal Medicine Service cIntensive Care Service dDiagnostic Imaging Service, Althaia Xarxa Hospitalaria i Universitària de Manresa, Universitat Internacional de Catalunya, Manresa, Spain.

Published: December 2014

Background: Abdominal ultrasound (US) may provide data on the presence of esophageal varices in cirrhosis. We assess the diagnostic accuracy of this procedure.

Patients And Methods: Retrospective recording of clinical data was carried out in cirrhotic patients who underwent abdominal US and upper gastrointestinal endoscopy. We compared patients with and without large varices and assessed the value of US in predicting the presence of these lesions as well as other significant variables.

Results: Of the 353 patients included, 123 (35%) had esophageal varices. The presence of US signs of portal hypertension independently predicted the existence of esophageal varices with a sensitivity of 87.9%, a specificity of 34.9%, a positive predictive value of 40.6%, and a negative predictive value of 85.1%, which could increase to 91.5% if the patient presented plasma albumin and platelet concentrations above the mean values (3.1 g/dl and 122×10 cells/l, respectively). Plasma albumin and platelet concentrations were the two other variables with independent predictive capacity. Applying these selection criteria, up to 30% of screening endoscopies may not be necessary, and up to 43% in patients with compensated cirrhosis. In patients with decompensated cirrhosis, however, US does not have predictive capacity. The results obtained are comparable with those reported for transient elastography.

Conclusion: Abdominal US is a highly reliable technique for detecting patients with a low risk of presenting esophageal varices. Its use may avoid up to 43% of screening endoscopies in patients with compensated cirrhosis. The results obtained are similar to those observed using transient elastography.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MEG.0000000000000174DOI Listing

Publication Analysis

Top Keywords

esophageal varices
20
diagnostic accuracy
8
abdominal ultrasound
8
patients
8
plasma albumin
8
albumin platelet
8
platelet concentrations
8
predictive capacity
8
screening endoscopies
8
patients compensated
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!