Deep brain stimulation evoked potentials may relate to clinical benefit in childhood dystonia.

Brain Stimul

Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA; Department of Neurology, University of Southern California and Children's Hospital Los Angeles, Los Angeles, CA, USA; Department of Biokinesiology and Physical Therapy, University of Southern California, Los Angeles, CA, USA. Electronic address:

Published: June 2015

Background: Deep brain stimulation (DBS) of the globus pallidus internus (GPi) is a treatment for severe childhood-onset dystonia. A common challenge for clinicians is determining which contacts of the DBS electrode to stimulate in order to provide maximum future benefit to the patient.

Objective: To characterize how the cortical responses to DBS relate to stimulation parameters (i.e. electrode contacts, voltage, and pulse width) and clinical outcomes.

Methods: We examined 11 patients with dystonia undergoing DBS therapy (9-21 years old when implanted). We varied the active contacts, voltage, and pulse width of the stimulating electrode and analyzed the deep-brain stimulator evoked potentials (DBSEPs) measured with electroencephalogram, and assessed symptoms with the Barry-Albright dystonia scale. Statistical tests included: Repeated measures ANOVA, Mann-Whitney U test and paired t-test.

Results: DBSEPs near sensorimotor areas were larger ipsilaterally than contralaterally (P = 0.007). The rate of DBSEP amplitude increase with respect to stimulator voltage (voltage gain) and pulse width (pulse width gain) varied across subjects and stimulating contacts. Voltage gains were significantly higher among patients who showed larger improvements with DBS (P = 0.038). Additionally, a within-subject comparison of all patients showed that voltage gains were higher for contacts chosen for chronic stimulation as compared to those that were not (P = 0.007).

Conclusions: DBSEPs may be good predictors of therapeutic response to stimulation at different electrode contacts. Furthermore, effective DBS therapy appears to modulate sensorimotor cortex. These findings may help clinicians optimize stimulator programming and may eventually lead to improved targeting during implantation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.brs.2014.06.003DOI Listing

Publication Analysis

Top Keywords

pulse width
16
contacts voltage
12
deep brain
8
brain stimulation
8
evoked potentials
8
electrode contacts
8
voltage pulse
8
dbs therapy
8
voltage gains
8
gains higher
8

Similar Publications

In this paper, we demonstrate a high-contrast front-end laser system based on Yb: YAG solid-state laser for Ti: sapphire terminal amplification. An ultrafast Yb: YAG solid-state laser is used to generate a broad-spectrum seed through white light generation (WLG), and then the signal light near 1600 nm is amplified by three-level colinear optical parametric chirped pulse amplification (OPCPA). Finally, a fs second harmonic generation (SHG) is used to obtain a laser output with a central wavelength of 795 nm, a pulse width of 40.

View Article and Find Full Text PDF

In this paper, a high-power UV-pumped BBO optical parametric oscillator (OPO) is presented by increasing the working temperature of the nonlinear crystal to fasten the color center recovery speed and further decrease the color center density. When the working temperature of the BBO crystal was experimentally increased from 135 °C to 185 °C, the output power was scaled up from 1.20 W to 2.

View Article and Find Full Text PDF

High-resolution optical diagnostics in the short wavelength infrared (SWIR II) region have gained significant attention in medical research, showing great potential for tissue spectroscopy and visualization due to the region's low water absorption and scattering coefficients. However, high-beam-quality sources covering an entire spectral range are limited. This paper presents the development of a femtosecond Cr:ZnSe laser with a 2.

View Article and Find Full Text PDF

Large energy single-frequency nanosecond (ns) near-infrared light source is an essential device in the field of the remote chemical analysis based on the laser-induced breakdown spectroscopy (LIBS). In this paper, a large energy single-frequency ns 824 nm light source with high repetition rate is presented, which is generated from a seed-injection locked optical parametric oscillator (OPO). By optimizing the spot radius of the pump laser and the mode-matching between the pump laser and signal light, the optical parametric generation (OPG) process is effectively eliminated.

View Article and Find Full Text PDF

A coherent optical frequency comb (OFC) with suppressed linewidth is demonstrated based on the spectral broadening of a directly modulated semiconductor microcavity laser with self-injection locking. Due to the high electro-optical response, the directly modulated microcavity laser provides a 10-GHz-spaced seeding OFC with 9 comb teeth in a 10 dB flatness window. Besides, an optical feedback fiber loop with two sub-loops is introduced to reduce the linewidth of the microlaser and suppress the undesired longitudinal modes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!