Roller pump infusion devices are widely used for rapid infusion, and may be combined with separate warming devices. There may be instances however, where the pressures generated by the roller pump may not be compatible with the warming device. We assessed a commonly used roller pump in combination with a HOTLINE® Fluid Warmer, and found that it could generate pressures exceeding the HOTLINE® manufacturers specifications. This was of concern because the HOTLINE® manufacturer guideline states that not for use with pressure devices generating over 300 mmHg. Pressure greater than 300 mmHg may compromise the integrity of the HOTLINE® Fluid Warming Set. The aim of this study was to compare in-line pressure within a HOTLINE® Fluid Warmer at different infusion rates of a roller pump using various sizes of intravenous cannulae. The rapid infusion system comprised a 500 mL-normal saline bag, roller pump type infusion device, HOTLINE® Fluid Warmer (blood and fluid warmer system), and six different sizes of intravenous cannulae. In-line pressure was measured proximal to the HOTLINE® (pre-warmer) and proximal to the cannula (post-warmer), at flow rate of 50-160 mL/min. The in-line pressures increased significantly with increasing flow rate. The pre-warmer pressures exceeded 300 mmHg when the flow rate was ≥120 mL/min with 20-gauge, 48 mm length cannula, 130 with 20-gauge, 25 mm cannula, and 160 mL/min with 18-gauge, 48 mm cannula. However, they were <300 mmHg at any flow rates with 18-gauge, 30 mm cannula and 16-gauge cannulae. The post-warmer pressures exceeded 300 mmHg at the flow rate of 140 mL/min with 20-gauge, 48 mm cannula, and 160 mL/min with 20-gauge, 25 mm cannula, while they were <300 mmHg at any flow rates with 18 and 16-gauge cannulae. The in-line pressure within a HOTLINE® could exceed 300 mmHg, depending on the flow rate and size and length of cannula. It is important to pay attention to the size and length of cannulae and flow rate to keep the maximum in-line pressure<300 mmHg when a roller pump type infusion device is used.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10877-014-9605-3 | DOI Listing |
Sports Med Open
January 2025
Mechanical Engineering Department, Texas Tech University, Lubbock, TX, USA.
Background: Drafting for drag reduction is a tactic commonly employed by elite athletes of various sports. The strategy has been adopted by Kenyan runner Eliud Kipchoge on numerous marathon events in the past, including the 2018 and 2022 editions of the Berlin marathon (where Kipchoge set two official world records), as well as in two special attempts to break the 2 h mark for the distance, the Nike Breaking2 (2017) and the INEOS 1:59 Challenge (2019), where Kipchoge used an improved drafting formation to finish in 1:59:40, although that is not recognized as an official record.
Results: In this study, the drag of a realistic model of a male runner is calculated by computational fluid dynamics for a range of velocities.
The ejaculatory reflex consists of emission and expulsion, with the latter involving rhythmic muscular contractions that propel seminal fluid. Botulinum toxin, through its inhibitory effects, has been hypothesized to improve premature ejaculation (PE). This study evaluates high-quality evidence on botulinum toxin-A injections into the bulbospongiosal muscle as a treatment for PE.
View Article and Find Full Text PDFCommun Med (Lond)
January 2025
Rare Disease Translational Center, The Jackson Laboratory, Bar Harbor, ME, USA.
Background: Multiple Sulfatase Deficiency (MSD) is a rare inherited lysosomal storage disorder characterized by loss of function mutations in the SUMF1 gene that manifests as a severe pediatric neurological disease. There are no available targeted therapies for MSD.
Methods: We engineered a viral vector (AAV9/SUMF1) to deliver working copies of the SUMF1 gene and tested the vector in Sumf1 knock out mice that generally display a median lifespan of 10 days.
Skeletal Radiol
January 2025
Department of Orthopedics and Traumatology, Helsinki University Hospital, University of Helsinki, Helsinki, Finland.
Objective: Total hip arthroplasty through the Hardinge approach damages the hip abductor muscles. MRI can be used to assess adverse postoperative events. In this prospective randomized controlled trial, we evaluated MRI findings and whether platelet-rich plasma affected postoperative healing of the gluteal muscles (gluteus medius and minimus).
View Article and Find Full Text PDFOphthalmologie
January 2025
Klinik für Augenheilkunde, Universitätsklinikum Ulm, Prittwitzstr. 43, 89075, Ulm, Deutschland.
Comprehensive multimodal imaging is essential for the precise clinical diagnostics of neovascular age-related macular degeneration (nAMD). Noninvasive optical coherence tomography (OCT) is of prime importance regarding the baseline examination, follow-up and monitoring during treatment. The OCT imaging in nAMD eyes enables a high-resolution assessment of the retinal micromorphology, which can be considerably disturbed in different layers.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!