A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An evaluation of the RapidHIT(®) system for reliably genotyping reference samples. | LitMetric

An evaluation of the RapidHIT(®) system for reliably genotyping reference samples.

Forensic Sci Int Genet

Institute of Applied Genetics, Department of Molecular and Medical Genetics, University of North Texas Health Science Center, Fort Worth, TX, USA; Center of Excellence in Genomic Medicine Research (CEGMR), King Abdulaziz University, Jeddah, Saudi Arabia.

Published: November 2014

Short tandem repeat (STR) typing is used routinely for associating or excluding individuals with biological evidence left at a crime scene. Improvements have been made to reduce the turnaround time and labor involved with profile generation, but there is still some lag time between sample collection and interpretation of results. The RapidHIT(®) (IntegenX; Pleasanton, CA, USA) system is an automated instrument that is configured to perform DNA extraction, bead-based DNA normalization, amplification, electrophoresis of PCR amplicons, and data analysis of five reference swabs simultaneously. The RapidHIT system provided reliable STR profiles from reference buccal swabs in approximately 90min with nominal "hands-on" sample loading time with no evidence of contamination between samples. The overall success rate of typing buccal swabs was comparable to standard typing systems. In the event of a failed run due to instrument failure, the swab can be removed from the cartridge and reanalyzed in the RapidHIT system or with standard STR genotyping workflows.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.fsigen.2014.06.012DOI Listing

Publication Analysis

Top Keywords

rapidhit system
8
buccal swabs
8
evaluation rapidhit®
4
system
4
rapidhit® system
4
system reliably
4
reliably genotyping
4
genotyping reference
4
reference samples
4
samples short
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!