A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A novel micellar per aqueous liquid chromatographic method for simultaneous determination of diltiazem hydrochloride, metoprolol tartrate and isosorbide mononitrate in human serum. | LitMetric

A novel micellar per aqueous liquid chromatographic method was investigated to simultaneously determine diltiazem hydrochloride, metoprolol tartrate and isosorbide mononitrate in human serum. Separation and determination of the analytes were performed on a Pinnacle II Cyano column as the stationary phase using the mobile phase consisted of aqueous solution (4.15×10(-2) mol/L sodium dodecyl sulfate and 0.02 mol/L sodium dihydrogen phosphate) with 10% (v/v) of 1-propanol at pH 7.0. This method was validated by linearity, lower limit of quantification, extraction recovery, stability, precision, and accuracy. The main analytical parameters were linearity (r>0.9950), intra- and inter-day precisions (intra-day RSD 2.2-3.5%, and inter-day RSD 3.7-9.5%), lower limit of quantification (20 ng mL(-1) for isosorbide mononitrate, metoprolol tartrate and diltiazem hydrochloride). The extraction recovery was 63.3% (0.1 μg/mL), 65.6% (1.0 μg/mL), and 69.5% (25 μg/mL) for isosorbide mononitrate; 65.1% (0.1 μg/mL), 69.5% (1.0 μg mL) and 73.5% (2.5 μg/mL) for metoprolol tartrate; 67.1% (0.1 μg/mL), 68.8% (1.0 μg/mL) and 73.8 % (2.5 μg/mL) for diltiazem hydrochloride. The relative error of stability was <6.4% at the room temperature for 24h, <3.8% at 4 °C for 1 week, <4.6% at -20 °C for 1 month, and <6.7% for freeze/thaw cycles (n=3). The results indicated that the proposed method was rapid, sensitive, and accurate for determination of the three antianginal drugs in human serum. The possible separation mechanism of the method was also discussed, and a model of separation mechanism for the analytes was established.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2014.07.019DOI Listing

Publication Analysis

Top Keywords

diltiazem hydrochloride
16
metoprolol tartrate
16
isosorbide mononitrate
16
novel micellar
8
micellar aqueous
8
aqueous liquid
8
liquid chromatographic
8
chromatographic method
8
hydrochloride metoprolol
8
tartrate isosorbide
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!