The influence of computational assumptions on analysing abdominal aortic aneurysm haemodynamics.

Proc Inst Mech Eng H

Galway Medical Technologies Centre (GMedTech), Department of Mechanical and Industrial Engineering, Galway-Mayo Institute of Technology, Galway, Ireland

Published: August 2014

AI Article Synopsis

Article Abstract

The variation in computational assumptions for analysing abdominal aortic aneurysm haemodynamics can influence the desired output results and computational cost. Such assumptions for abdominal aortic aneurysm modelling include static/transient pressures, steady/transient flows and rigid/compliant walls. Six computational methods and these various assumptions were simulated and compared within a realistic abdominal aortic aneurysm model with and without intraluminal thrombus. A full transient fluid-structure interaction was required to analyse the flow patterns within the compliant abdominal aortic aneurysms models. Rigid wall computational fluid dynamics overestimates the velocity magnitude by as much as 40%-65% and the wall shear stress by 30%-50%. These differences were attributed to the deforming walls which reduced the outlet volumetric flow rate for the transient fluid-structure interaction during the majority of the systolic phase. Static finite element analysis accurately approximates the deformations and von Mises stresses when compared with transient fluid-structure interaction. Simplifying the modelling complexity reduces the computational cost significantly. In conclusion, the deformation and von Mises stress can be approximately found by static finite element analysis, while for compliant models a full transient fluid-structure interaction analysis is required for acquiring the fluid flow phenomenon.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0954411914546122DOI Listing

Publication Analysis

Top Keywords

abdominal aortic
20
aortic aneurysm
16
transient fluid-structure
16
fluid-structure interaction
16
computational assumptions
8
assumptions analysing
8
analysing abdominal
8
aneurysm haemodynamics
8
computational cost
8
full transient
8

Similar Publications

Robotic-assisted excision of left para-aortic paraganglioma: a novel approach.

J Surg Case Rep

January 2025

Department of Endocrine Surgery, Royal Victoria Infirmary, Newcastle Upon Tyne NE1 4LP, United Kingdom.

Paragangliomas, a type of extra-adrenal tumour, albeit rare, are dangerous due to their high metastatic potential and risk of hypertensive crisis from massive catecholamine release. It typically presents with sympathetic overdrive symptoms such as diaphoresis, headache, and palpitation, accompanied by substantially high plasma metanephrines level and mass on contrasted computed tomography abdomen and pelvis, whilst some are found incidentally. In this report, we discuss a case of an extra-adrenal lesion located near susceptible major structures with extensive vascularisation, in a patient with near-death experience.

View Article and Find Full Text PDF

Type B Aortic Dissection Secondary to Non-typhoidal Salmonella Aortitis: A Case Report and Literature Review.

J Community Hosp Intern Med Perspect

November 2024

Department of Nursing, Karnali Academy of Health Science, Jumla, Nepal.

Infectious aortitis is an uncommon but potentially fatal condition that can lead to aortic dissection or rupture. We describe a case of a 69-year-old female who developed a Stanford type B aortic dissection, presumptively caused by Salmonella, which was successfully managed with thoracic endovascular aneurysm repair (TEVAR) and long-term antibiotics. A literature review of 17 reported cases from 2000 to 2024 of aortic dissection secondary to infectious aortitis was conducted.

View Article and Find Full Text PDF

Background: The bolus tracking technique has been used for decades, yet still faces the challenging task of determining the optimal scanning time for individuals. Our study aimed to assess the feasibility of a novel bolus tracking method with a personalized post-trigger delay (PTD) to optimize scanning time and achieve optimized enhancement and contrast homogeneity in aortic computed tomography angiography (CTA).

Methods: Participants undergoing aortic CTA with bolus tracking were prospectively assigned to two different groups: Group A with a fixed 6-second PTD and Group B with a personalized PTD.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!