Objectives: Untreated severe scoliosis is associated with increased mortality and remains a significant surgical challenge. Few studies have reported mortality after the surgical treatment of severe scoliosis beyond a 2-year follow-up. The objectives of this study were to evaluate mortality beyond standard 2-year follow-up and compare radiographic outcomes using hybrid or pedicle screw instrumentation for severe scoliosis.

Methods: We evaluated 32 consecutive patients [11 males, mean age at surgery 15.3 (range 10.7-20.7) years] operated for a scoliosis of 90° or more using either hybrid (n = 15) or pedicle screw (n = 17) instrumentation. The follow-up time averaged 2.9 (2.0-6.6) years for radiographic and quality of life measurements and 5.5 years (2.0-9.0) years for mortality data. Of these patients, one had adolescent idiopathic scoliosis, three secondary scoliosis, and 28 neuromuscular scoliosis. Twelve patients in the hybrid and two patients in the pedicle screw groups underwent anteroposterior surgery (p < 0.001), and three patients in both groups had an apical vertebral column resection.

Results: One (3.1 %) patient died during follow-up for severe pneumonia. Preoperatively, the mean magnitude of the major curve was 109° (90°-127°) in the hybrid and 100° (90°-116°) in the pedicle screw groups (p = 0.015), and was corrected to 45° (19°-69°) in the hybrid and 27° (18°-40°) in the pedicle screw groups at the 2-year follow-up (p < 0.001), with a mean correction of the major curve of 59 % (37-81 %) in the hybrid versus 73 % (60-81 %) in the pedicle screw groups, respectively (p = 0.0023). There were six postoperative complications, including one transient spinal cord deficit necessitating reoperation in the hybrid group as compared with five complications in the pedicle screw group (p = 0.53).

Conclusions: The mid-term mortality rate after the surgical treatment of severe scoliosis was low. Severe scoliosis can be treated safely with significantly better correction of the spinal deformity using pedicle screws than hybrid instrumentation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4128946PMC
http://dx.doi.org/10.1007/s11832-014-0604-1DOI Listing

Publication Analysis

Top Keywords

pedicle screw
16
severe scoliosis
12
radiographic outcomes
8
scoliosis 90°
8
screw instrumentation
8
2-year follow-up
8
scoliosis
7
morbidity radiographic
4
severe
4
outcomes severe
4

Similar Publications

Objectives: The advent of O-arm navigation optimized the oblique lumbar interbody fusion (OLIF) procedure, allowing the operator to simultaneously perform OLIF and percutaneous posterior pedicle screw implantation without patient position change, thus improving the fluency and accuracy of the OLIF procedure (called as OLIF360). Nevertheless, a consensus regarding its suitability for patients with severe spinal stenosis remains elusive. This study aims to investigate the clinical efficacy of OLIF360 and its imaging changes in severe lumbar spinal stenosis cases.

View Article and Find Full Text PDF

Background: Tropical Candida spondylitis is an uncommon cause of lower back pain in patients, especially in non-tropical areas or in patients not at risk of immunocompromise.

Case Presentation: A 65-year-old woman presented with a six-month history of poorly managed low back pain, now accompanied by numbness and pain in both lower extremities. Her medical history was significant for tertiary hypertension.

View Article and Find Full Text PDF

This descriptive longitudinal study aims to assess the risk factors for severe thoracic and lumbar vertebral compression fractures before and after surgery, contributing to preventive knowledge enhancement in communities and effective treatment management. The study involved 34 patients diagnosed with thoracic and lumbar vertebral compression fractures requiring surgery with bio-cement-augmented pedicle screws between June 2021 and June 2022. Postoperative complications, notably adjacent segment injury, were monitored, and patients received osteoporosis management post-surgery.

View Article and Find Full Text PDF

Cement-augmented pedicle screw instrumentation is a widely accepted method for managing osteoporotic fractures, but it carries inherent risks, particularly related to cement leakage and embolism. This study aimed to analyze a clinical case of complications following cement fixation and provide a detailed review of relevant literature. A 70-year-old patient underwent transpedicular screw instrumentation from L2-L4 with polymethyl methacrylate augmentation, which resulted in cement leakage into the spinal canal and subsequent pulmonary embolism.

View Article and Find Full Text PDF

Osteoporotic vertebral fractures (OVFs) in elderly patients pose challenges due to bone destruction and surgical risks. This case report describes a minimally invasive approach using calcium phosphate cement (CPC) vertebroplasty and short fusion with cement augmentation of pedicle screws (CAPS) in a 91-year-old woman with severe OVF. The patient underwent CPC vertebroplasty at L1 and CAPS fixation at T12-L2, followed by osteoporosis medication.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!