Effect of muscle length on voluntary activation level in children and adults.

Med Sci Sports Exerc

1EA 3533, Laboratory of Metabolic Adaptations during Exercise in Physiological and Pathological Conditions (AME2P), Clermont University, Blaise Pascal University, Aubière, FRANCE; 2Department of Movement Sciences, Oxylane Research, Villeneuve d'Ascq, FRANCE; 3Clermont University Hospital, Clermont-Ferrand, FRANCE; 4INRA, Human Nutrition Unit (UMR 1019), CRNH Auvergne, Clermont-Ferrand, FRANCE; and 5Clermont University, Auvergne University, Clermont-Ferrand, FRANCE.

Published: April 2015

Purpose: The aim of the present study was to compare the effect of muscle length on the level of voluntary activation (VA) at short and long muscle lengths between children and adults.

Methods: Thirteen prepubertal boys (10.2 ± 1.1 yr) and 10 men (23.9 ± 2.9 yr) performed 5-s maximal isometric voluntary contractions of the knee extensor muscles at three muscular angles (20°, 90°, 100°; 0°, full extension) interspersed with at least 60-s passive recovery periods. Single magnetic stimulations were delivered to the femoral nerve during maximal isometric voluntary contractions to determine the level of VA using the twitch interpolation technique. The specific torque was calculated as the absolute torque divided by thigh muscle mass, as assessed using dual-energy x-ray absorptiometry. Finally, the theoretical specific torque that could be produced with a complete (i.e., 100%) activation level (specific torque at 100% VA) was estimated from the values of specific torque and VA.

Results: Results showed a higher specific torque in adults at 90° and 100° but not at 20°. Accordingly, VA was significantly higher in adults at 90° (94% ± 4% vs 88% ± 8%, P < 0.05) and 100° (93% ± 6% vs 86% ± 8%, P < 0.05), whereas no significant difference was observed at 20°. Interestingly, the specific torque at 100% VA was not different between groups whatever the joint angle.

Conclusions: The lower ability of children to fully activate their motor units at long muscle length could account for their lower specific torque because no difference in theoretical specific torque was observed between groups at 90° and 100°.

Download full-text PDF

Source
http://dx.doi.org/10.1249/MSS.0000000000000463DOI Listing

Publication Analysis

Top Keywords

specific torque
32
muscle length
12
90° 100°
12
torque
9
voluntary activation
8
activation level
8
long muscle
8
maximal isometric
8
isometric voluntary
8
voluntary contractions
8

Similar Publications

Immune-checkpoint inhibitors (ICIs) have improved clinical outcomes across several solid tumour types. Prominent efforts have focused on understanding the anticancer mechanisms of these agents, identifying biomarkers of response and uncovering resistance mechanisms to develop new immunotherapeutic approaches. This research has underscored the crucial roles of the tumour microenvironment and, particularly, tumour-infiltrating lymphocytes (TILs) in immune-mediated tumour elimination.

View Article and Find Full Text PDF

The effect of Torque Teno Virus (TTV) Infection on Clinical Outcomes, Genomic Integrity, and Mortality in COPD Patients.

Mech Ageing Dev

January 2025

San Raffaele University; Department of Human Sciences and Promotion of the Quality of Life, Via di Val Cannuta 247, 00166 Rome, Italy; Clinical and Molecular Epidemiology, IRCCS San Raffaele Roma, Via di Val Cannuta 247, 00166 Rome, Italy. Electronic address:

Introduction: Torque Teno Virus (TTV), an "orphan" virus with unclear pathology, has been associated with various diseases and immune dysfunctions. This study investigates the link between TTV viremia and clinical markers in patients with severe to very severe COPD undergoing respiratory rehabilitation.

Methods: We analyzed 102 elderly COPD patients, stratified by TTV viremia levels (< or ≥ 4 log10 copies/mL).

View Article and Find Full Text PDF

Introduction: Load carriage is an inherent part of tactical operations. Critical speed (CS) has been associated with technical and combat-specific performance measures (e.g.

View Article and Find Full Text PDF

Novel Design on Knee Exoskeleton with Compliant Actuator for Post-Stroke Rehabilitation.

Sensors (Basel)

December 2024

Institute of Robotics, Autonomous System and Sensing, School of Electronic and Electrical Engineering, University of Leeds, Leeds LS2 9JT, UK.

Knee joint disorders pose a significant and growing challenge to global healthcare systems. Recent advancements in robotics, sensing technologies, and artificial intelligence have driven the development of robot-assisted therapies, reducing the physical burden on therapists and improving rehabilitation outcomes. This study presents a novel knee exoskeleton designed for safe and adaptive rehabilitation, specifically targeting bed-bound stroke patients to enable early intervention.

View Article and Find Full Text PDF

Load-bearing capacity of screw-retained fixed dental prostheses made of monolithic zirconia on different abutment designs and abutment-free implant connection.

J Dent

January 2025

Senior Research and Teaching Assistant, Clinic of Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich 8032, Switzerland. Electronic address:

Objectives: A new abutment-free implant connection allows for direct screwing of FDPs on implants to avoid complications caused by cement rests or screw loosening, which may affect to screw torque and load distribution. The objective of this study was to test the initial (Fi) and final failure (Ff) loads and torque changes of abutment-free monolithic zirconia CAD-CAM fixed dental prostheses (FDPs) compared to titanium FDPs on different abutment designs.

Methods: Three-unit screw-retained FDPs (n = 50) on two implants (n = 100) were divided into groups (n = 10) based on the implant-abutment connection and material of the supra-structure: (1) abutment-free monolithic CAD-CAM zirconia FDP (Abut-free-Zr), (2) abutment-free veneered titanium FDPs (Abut-free-Ti), (3) monolithic zirconia FDPs with titanium base abutments (Zr-Ti-Base), (4) monolithic zirconia FDPs on multi-unit abutments (Zr-MU), (5) veneered titanium FDP on multi-unit abutments (Ti-MU).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!