A high-throughput, rapid, and efficient modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) method with a simple cleanup procedure has been developed for simultaneously determining 227 pesticides in pepper samples by liquid chromatography with tandem mass spectrometry (running time: 10 min). Pesticide residues were extracted/partitioned with an acetonitrile/DisQuE QuEChERS pouch, and the resulting samples were cleaned up with different methods: dispersive solid-phase extraction with primary secondary amines or multiwalled carbon nanotubes and graphitized carbon solid mini cartridge column. The results indicated that multiwalled carbon nanotubes dispersive sorbents achieved the best recoveries and had less matrix interference. The numbers of pesticides with a recovery in the range of 70-120% were 199 at a spiked level of 40 μg/kg. The correlation coefficients (r(2)) for 227 pesticides were above 0.99, while the limits of quantitation of pesticides in pepper samples ranged from 0.13 to 13.51 μg/kg (S/N = 10), and the limits of detection ranged from 0.04 to 4.05 μg/kg (S/N = 3). The relative standard deviations of approximately 197 pesticides were below 20% at spiked levels of 40 μg/kg. Based on these results, the proposed method was chosen as the most suitable cleanup procedure for the determination of multiresidue pesticides in pepper samples.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jssc.201400536DOI Listing

Publication Analysis

Top Keywords

227 pesticides
12
pesticides pepper
12
pepper samples
12
liquid chromatography
8
chromatography tandem
8
tandem mass
8
mass spectrometry
8
cleanup procedure
8
multiwalled carbon
8
carbon nanotubes
8

Similar Publications

Hierarchical structures of surface-accessible plasmonic gold and silver nanoparticles for SERS detection.

Soft Matter

January 2025

Faculty of Chemistry, Ho Chi Minh City University of Science, Vietnam National University, Ho Chi Minh City, 227 Nguyen Van Cu Street, Ward 4, District 5, Ho Chi Minh City 70000, Vietnam.

Surface-enhanced Raman spectroscopy (SERS) is a highly sensitive analytical technique with excellent molecular specificity. However, separate pristine nanoparticles produce relatively weak Raman signals. It is necessary to focus on increasing the "hot-spot" density generated at the nanogaps between the adjacent nanoparticles (second-generation SERS hotspot), thus significantly boosting the Raman signal by creating an electromagnetic field.

View Article and Find Full Text PDF

Ecotoxicological bioassays with terrestrial plants: a holistic view of standards, guidelines, and protocols.

J Toxicol Environ Health B Crit Rev

January 2025

Department of Ecology and Conservation, Institute of Natural Sciences, Federal University of Lavras, Lavras, MG, Brazil.

Terrestrial and aquatic ecosystems face various chemicals that might induce acute and/or long-term harm. To assess these impacts, ecotoxicological bioassays are essential. However, bioassays using animals, particularly mammals, are costly, time-consuming, and raise ethical concerns.

View Article and Find Full Text PDF

Surface layer (S-layer) is an extracellular proteinous layer consisting of two-dimensional lattice. It is typically present on archaea and also found on some bacteria. S-layer proteins from some bacteria are reported to be toxic to mosquito larvae.

View Article and Find Full Text PDF

Background: Insecticides are a crucial component of vector control. However, resistance constitute a threat on their efficacy and the gains obtained over the years through malaria vector control. In Gabon, little data on phenotypic insecticide resistance in Anopheles vectors are published, compromising the rational implementation of resistance management strategies.

View Article and Find Full Text PDF

Multiple non-targeted analysis tools were used to look for a broad range of possible chemical contaminants present in surface and drinking water using liquid chromatography separation and high-resolution mass spectrometry detection, including both quadrupole time of flight (Q-ToF) and Orbitrap instruments. Two chromatographic techniques were evaluated on an LC-Q-ToF with electrospray ionization in both positive and negative modes: (1) the traditionally used reverse phase C18 and (2) the hydrophilic interaction liquid chromatography (HILIC) aimed to capture more polar contaminants that may be present in water. Multiple ionization modes were evaluated with an LC-Orbitrap, including electrospray (ESI) and atmospheric pressure chemical ionization (APCI), also in both positive and negative modes.