Radial head prosthesis in complex elbow dislocations: effect of oversizing and comparison with ORIF.

Int Orthop

Berufsgenossenschaftliche Unfallklinik Ludwigshafen, Abteilung für Unfallchirurgie und Orthopädie, Ludwig Guttmann Strasse 13, 67071, Ludwigshafen on the Rhine, Germany.

Published: November 2014

Purpose: Elbow dislocations with complex elbow instability (CEI) and unstable radial head fractures require reconstruction by open reduction and internal fixation (ORIF) if possible or alternatively by a radial head prosthesis. The aim of this study was to determine the differential outcome of both strategies and to investigate the contribution of prosthesis-related radiographic factors such as oversizing on clinical outcome.

Methods: A total of 53 patients underwent ligament and coronoid refixation, and radial head reconstruction by ORIF (n = 18; group 1) or by monopolar modular prosthesis (n = 35; group 2). Patients were followed by the Mayo Elbow Performance Score (MEPS) and a radiological score including prosthesis oversizing, joint subluxation, ossifications, capitellar erosions, implant loosening and ulno-humeral osteoarthritis. To investigate the effect of oversizing, group 2 was subdivided by prosthesis overlenghtening ≥ 2 mm.

Results: A total of 42 patients (79.2%) could be followed for 3.0 ± 1.3 years with an average MEPS of 76.8 ± 17.2. Patients with ORIF had slightly better MEPS (82.1 ± 9.9) as compared with group 2 (74.7 ± 19.1) though three ORIF patients required an early conversion to prosthesis. In group 2, oversizing occurred frequently and 50% showed an overlenghtening ≥ 2 mm. Oversizing significantly decreased MEPS (63.2 ± 21.3 vs 84.7 ± 9.0; p = 0.001) and elbow range of motion and increased the occurrence of other radiological abnormalities and the risk for surgical revisions. The radiological score and prosthesis overlenghtening but not prosthesis diameter showed an inverse correlation with MEPS.

Conclusions: In CEI a radial head reconstruction with a prosthesis demonstrates similarly good clinical results as compared to ORIF in anatomically sized prosthesis, but prosthesis oversizing could induce other radiographic abnormalities with then deteriorated outcome.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00264-014-2478-8DOI Listing

Publication Analysis

Top Keywords

radial head
20
prosthesis
11
head prosthesis
8
complex elbow
8
elbow dislocations
8
total patients
8
head reconstruction
8
radiological score
8
prosthesis oversizing
8
oversizing
7

Similar Publications

Functional soft palate reconstruction.

JPRAS Open

March 2025

Department of Plastic, Reconstructive, Aesthetic, and Hand Surgery, University Hospital Basel, Basel, Switzerland.

Background: The excision of oropharyngeal carcinoma of more than 50% of the soft palate followed by static reconstruction may result in functional deficits, including velopharyngeal insufficiency, swallowing, and speech difficulties. We describe a functional soft palate reconstruction technique aimed at restoring aeromechanical and acoustic functions, enabling swallowing without nasal regurgitation and speech with low nasalance.

Material And Methods: We developed a new operative technique, using muscle transfer and a free flap to create a dynamic reconstruction.

View Article and Find Full Text PDF

The use of proteins as intracellular probes and therapeutic tools is often limited by poor intracellular delivery. One approach to enabling intracellular protein delivery is to transform proteins into spherical nucleic acid (proSNA) nanoconstructs, with surfaces chemically modified with a dense shell of radially oriented DNA that can engage with cell-surface receptors that facilitate endocytosis. However, proteins often have a limited number of available reactive surface residues for DNA conjugation such that the extent of DNA loading and cellular uptake is restricted.

View Article and Find Full Text PDF

Objective: Complex ablative maxillary and mandibular defects often require osseous free flap reconstruction. Workhorse options include the fibula, scapula, and osteocutaneous radial forearm flap (OCRFF). The choice of donor site for harvest should be driven not only by reconstructive goals but also by donor site morbidity.

View Article and Find Full Text PDF

Introduction: Osteochondroma is a bony lesion arising from the surface of the bone. It com-prises a large percentage of all benign bone tumors. A unique feature of this tumor is the conti-nuity of cortical and medullary components between the normal bony tissue and aberrant tissue of osteochondroma.

View Article and Find Full Text PDF

Trends in treatment and epidemiology of radial head fractures.

Shoulder Elbow

January 2025

Rothman Orthopaedics Florida at AdventHealth, Orlando, FL, USA.

Objective: We aimed to assess the recent trends in the demographics of radial head and neck fractures and their management based on displacement.

Methods: TriNetX was queried for cases from 1 January 2017, through 31 December 2022. ICD diagnosis codes were used to define patient cohorts with radial head or neck fractures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!