Vacuum ultraviolet detector for gas chromatography.

Anal Chem

Department of Chemistry & Biochemistry, The University of Texas at Arlington, 700 Planetarium Place, Box 19065, Arlington, Texas 76019, United States.

Published: August 2014

Analytical performance characteristics of a new vacuum ultraviolet (VUV) detector for gas chromatography (GC) are reported. GC-VUV was applied to hydrocarbons, fixed gases, polyaromatic hydrocarbons, fatty acids, pesticides, drugs, and estrogens. Applications were chosen to feature the sensitivity and universal detection capabilities of the VUV detector, especially for cases where mass spectrometry performance has been limited. Virtually all chemical species absorb and have unique gas phase absorption cross sections in the approximately 120-240 nm wavelength range monitored. Spectra are presented, along with the ability to use software for deconvolution of overlapping signals. Some comparisons with experimental synchrotron data and computed theoretical spectra show good agreement, although more work is needed on appropriate computational methods to match the simultaneous broadband electronic and vibronic excitation initiated by the deuterium lamp. Quantitative analysis is governed by Beer-Lambert Law relationships. Mass on-column detection limits reported for representatives of different classes of analytes ranged from 15 (benzene) to 246 pg (water). Linear range measured at peak absorption for benzene was 3-4 orders of magnitude. Importantly, where absorption cross sections are known for analytes, the VUV detector is capable of absolute determination (without calibration) of the number of molecules present in the flow cell in the absence of chemical interferences. This study sets the stage for application of GC-VUV technology across a wide breadth of research areas.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac5018343DOI Listing

Publication Analysis

Top Keywords

vuv detector
12
vacuum ultraviolet
8
detector gas
8
gas chromatography
8
absorption cross
8
cross sections
8
detector
4
ultraviolet detector
4
chromatography analytical
4
analytical performance
4

Similar Publications

Ultra-high PDCR(>10) of vacuum-UV photodetector based on Al-doped GaOmicrobelts.

Nanotechnology

October 2024

Key Laboratory of Advanced Semiconductor Devices and Materials, School of Electronic Engineering, Xi'an University of Posts and Telecommunications, Xi'an 710121, People's Republic of China.

Article Synopsis
  • Al-doped Ga2O3 microbelts were developed using carbothermal reduction, with impressive dimensions of 20 to 154 μm in width and up to 2 mm in length.
  • The resulting photoconductive UV detectors demonstrated outstanding performance at 185 nm, achieving a high photocurrent of 192.07 μA and an exceptional light-to-dark current ratio of 1.23×10^9.
  • The study highlights the potential of Al-doped Ga2O3 microbelts for VUV photodetectors, showcasing superior selectivity and responsivity compared to detectors targeting longer UV wavelengths.
View Article and Find Full Text PDF

Determination of olefins in pyrolysis oils from waste plastics and tires is crucial for optimizing the pyrolysis process and especially for the further advanced valorization of these oils in terms of the circular economy. Identifying olefins, even using high-resolution techniques like GC×GC, is challenging without TOF-MS, which allows modification of the ionization step. Currently, the only method for determining olefins in plastic pyrolysis oils is GC-VUV, recently standardized as ASTM D8519.

View Article and Find Full Text PDF
Article Synopsis
  • The first mirror in fusion plasmas reflects light to the diagnostic system and is made from silicon carbide (SiC) for its strength and radiation resistance.
  • A device was developed to measure the reflectivity of the SiC mirror at specific angles using a hollow cathode lamp and a dedicated VUV spectrometer.
  • Experimental results showed that the reflectivity values of SiC were influenced by both the oxidation layer on the surface and the incidence angle of the VUV light.
View Article and Find Full Text PDF

Timing limits of ultrafast cross-luminescence emission in CsZnCl-based crystals for TOF-CT and TOF-PET.

EJNMMI Phys

July 2024

Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany.

Background: Good timing resolution in medical imaging applications such as TOF-CT or TOF-PET can boost image quality or patient comfort significantly by reducing the influence of background noise. However, the timing resolution of state-of-the-art detectors in CT and PET are limited by their light emission process. Core-valence cross-luminescence is an alternative, but well-known compounds (e.

View Article and Find Full Text PDF

In the modern world, energy and fuels are of utmost importance. Rapid characterization of petroleum and other hydrocarbon-based fuel is a well-researched field. Gas chromatography has traditionally been used to separate the different species and characterize the chemical content in fuels.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!