Analytical performance characteristics of a new vacuum ultraviolet (VUV) detector for gas chromatography (GC) are reported. GC-VUV was applied to hydrocarbons, fixed gases, polyaromatic hydrocarbons, fatty acids, pesticides, drugs, and estrogens. Applications were chosen to feature the sensitivity and universal detection capabilities of the VUV detector, especially for cases where mass spectrometry performance has been limited. Virtually all chemical species absorb and have unique gas phase absorption cross sections in the approximately 120-240 nm wavelength range monitored. Spectra are presented, along with the ability to use software for deconvolution of overlapping signals. Some comparisons with experimental synchrotron data and computed theoretical spectra show good agreement, although more work is needed on appropriate computational methods to match the simultaneous broadband electronic and vibronic excitation initiated by the deuterium lamp. Quantitative analysis is governed by Beer-Lambert Law relationships. Mass on-column detection limits reported for representatives of different classes of analytes ranged from 15 (benzene) to 246 pg (water). Linear range measured at peak absorption for benzene was 3-4 orders of magnitude. Importantly, where absorption cross sections are known for analytes, the VUV detector is capable of absolute determination (without calibration) of the number of molecules present in the flow cell in the absence of chemical interferences. This study sets the stage for application of GC-VUV technology across a wide breadth of research areas.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/ac5018343 | DOI Listing |
Nanotechnology
October 2024
Key Laboratory of Advanced Semiconductor Devices and Materials, School of Electronic Engineering, Xi'an University of Posts and Telecommunications, Xi'an 710121, People's Republic of China.
Talanta
January 2025
Department of Sustainable Fuels and Green Chemistry, University of Chemistry and Technology Prague, Technická 5, 166 28 Prague 6, Czech Republic.
Determination of olefins in pyrolysis oils from waste plastics and tires is crucial for optimizing the pyrolysis process and especially for the further advanced valorization of these oils in terms of the circular economy. Identifying olefins, even using high-resolution techniques like GC×GC, is challenging without TOF-MS, which allows modification of the ionization step. Currently, the only method for determining olefins in plastic pyrolysis oils is GC-VUV, recently standardized as ASTM D8519.
View Article and Find Full Text PDFRev Sci Instrum
August 2024
Department of Energy Systems Research, Ajou University, 206 Worldcup-ro, Suwon 16499, South Korea.
EJNMMI Phys
July 2024
Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany.
Background: Good timing resolution in medical imaging applications such as TOF-CT or TOF-PET can boost image quality or patient comfort significantly by reducing the influence of background noise. However, the timing resolution of state-of-the-art detectors in CT and PET are limited by their light emission process. Core-valence cross-luminescence is an alternative, but well-known compounds (e.
View Article and Find Full Text PDFIn the modern world, energy and fuels are of utmost importance. Rapid characterization of petroleum and other hydrocarbon-based fuel is a well-researched field. Gas chromatography has traditionally been used to separate the different species and characterize the chemical content in fuels.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!