A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment of anterior and posterior corneal indices using two Scheimpflug analyzers. | LitMetric

Purpose: To assess the agreement between the elevation and curvature measurements of the anterior and posterior corneal surfaces obtained using the Galilei Dual Scheimpflug Analyzer and those obtained using the Pentacam single Scheimpflug system.

Methods: This prospective, noninterventional, diagnostic study was conducted at the Department of Ophthalmology at the American University of Beirut (Medical Center) and included 60 eyes of 60 consecutive patients. Measurements were obtained using 2 different Scheimpflug analyzers (Galilei and Pentacam). The best-fit sphere was set at 8 mm in both machines. Pachymetry (CCT), anterior elevation (AE) and posterior elevation (PE), and curvature were assessed. Pearson's correlation coefficients, comparison of means, and Bland-Altman plots were used to evaluate agreement between the 2 systems.

Results: The average CCT (at the corneal apex) was 533 ± 35 µm and 532 ± 37 µm (p=0.980), the average central AE was 1.25 ± 3.95 µm and 2.29 ± 5.28 µm (p=0.964), and the average central PE was 4.19 ± 8.18 µm and 5.42 ± 14.05 (p=0.956) µm with the Galilei and Pentacam, respectively.

Conclusion: The Scheimpflug analyzers correlated well in the assessment of pachymetry, elevation, and curvature.

Download full-text PDF

Source
http://dx.doi.org/10.5935/0004-2749.20140006DOI Listing

Publication Analysis

Top Keywords

scheimpflug analyzers
12
elevation curvature
12
anterior posterior
8
posterior corneal
8
galilei pentacam
8
average central
8
µm
6
scheimpflug
5
assessment anterior
4
corneal indices
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!