A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Detection and characterization of focal liver lesions by split-bolus multidetector-row CT: diagnostic accuracy and radiation dose in oncologic patients. | LitMetric

Aim: To assess the diagnostic accuracy and radiation dose of split-bolus multidetector-row computed tomography (MDCT) protocol in the detection and characterization of focal liver lesions in oncologic patients.

Patients And Methods: We retrospectively analyzed triphasic CT at initial diagnosis and follow-up split-bolus 64-detector row CT protocol in 48 oncologic patients with focal liver lesions. Split-bolus MDCT protocol by i.v. injection of two boli of contrast medium combines hepatic arterial phase (HAP) and hepatic enhancement during portal venous phase (PVP) in a single pass. First bolus: 75-90 mL at 2.0 mL/sec to obtain adequate hepatic enhancement during the PVP; second bolus: 60 mL/sec at 3.5 mL/sec to ensure HAP. Each bolus is followed by 20 mL of saline solution at the same flow rate. Sensitivity, specificity, positive predictive value and negative predictive value of split-bolus MDCT protocol were calculated for detection and characterization of liver lesions. The effective radiation dose (ED) was calculated using dose-length product (DLP) values in mSv determined using a conversion factor.

Results: compared to triphasic-MDCT, split-bolus MDCT protocol confirmed all the 210 lesions identified and characterized by triphasic-MDCT technique, unchanged during the follow-up. The mean ED was 27.8 ± 6 mSv for chest-abdomen-pelvis biphasic split-bolus MDCT and 45.7 ± 13.6 mSv for triphasic-MDCT.

Conclusion: The diagnostic efficacy of split-bolus protocol is comparable to that of triphasic protocol at MDCT with a reduction in radiation dose of approximately 35-40%.

Download full-text PDF

Source

Publication Analysis

Top Keywords

liver lesions
16
radiation dose
16
mdct protocol
16
split-bolus mdct
16
detection characterization
12
focal liver
12
characterization focal
8
split-bolus
8
lesions split-bolus
8
split-bolus multidetector-row
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!