AI Article Synopsis

  • The study explores a multi-step method for accurately measuring urinary nucleosides using capillary electrophoresis with UV detection (CE-UVD), integrating dynamic pH junction, sweeping, and large volume sample stacking techniques.
  • Key factors affecting separation and enrichment are examined, including buffer concentration and sample composition, while a novel extraction process using phenylboronate affinity gel is utilized for selectively capturing nucleosides from urine.
  • The method achieves a detection limit of 10 ng/mL, the lowest reported for nucleoside analysis with CE-UVD, demonstrating strong potential for analyzing nucleosides in urine and biological fluids.

Article Abstract

The combination of dynamic pH junction, sweeping (using borate complexation), and large volume sample stacking (LVSS) is investigated as three consecutive steps for on-line focusing in the sensitive quantitation of urinary nucleosides by CE-UVD. A low conductivity aqueous sample matrix free from borate and a high conductivity BGE (containing borate, pH 9.25) are needed to fulfill the required conditions for dynamic pH junction, LVSS, and sweeping. Parameters affecting the separation and the enrichment efficiency are studied such as buffer concentration, separation voltage, capillary temperature, sample composition, and sample injection volume. Prerequisite for the developed strategy is the extraction of the nucleosides from urine using a phenylboronate affinity gel, which is described to be a unique means for the selective enrichment of cis-diol metabolites under alkaline conditions. The impact of ionic constituents remaining in the eluate after extraction on focusing efficiency and resolution is investigated. The developed method is applied to the analysis of blank and spiked urine samples. Fundamental aspects underlying the proposed enrichment procedure are discussed. A detection limit as low as 10 ng mL(-1) is achieved. To the best of our knowledge, this LOD represents the lowest LOD reported so far for the analysis of nucleosides using CE with UV detection and provides a comparable sensitivity to CE/MS. Because of the high sensitivity, the proposed method shows a great potential for the analysis of nucleosides in human urine and other types of biological fluids.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-014-8022-2DOI Listing

Publication Analysis

Top Keywords

urinary nucleosides
8
borate complexation
8
volume sample
8
sample stacking
8
steps on-line
8
dynamic junction
8
analysis nucleosides
8
nucleosides
5
sample
5
determination urinary
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!