A multi-step method with signal quality assessment and fine-tuning procedure to locate maternal and fetal QRS complexes from abdominal ECG recordings.

Physiol Meas

School of Information Science and Engineering, Shandong University, Jinan, 250100, People's Republic of China. School of Control Science and Engineering, Shandong University, Jinan, 250061, People's Republic of China.

Published: August 2014

Non-invasive monitoring of fetal electrocardiogram (fECG) plays an important role in detecting and diagnosing fetal diseases. This study aimed to develop a multi-step method for locating both maternal and fetal QRS complexes from abdominal ECG (aECG) recordings. The proposed method included four major steps: abdominal ECG pre-processing, maternal QRS complex locating, maternal ECG cancellation and fetal QRS complex locating. Signal quality assessment (SQA) and fine-tuning for maternal ECG (FTM) were implemented in the first and third steps, respectively. The method was then evaluated using 75 non-invasive 4-channel aECG recordings provided by the PhysioNet/Computing in Cardiology Challenge 2013. The F1 measure, which is a new index introduced by Behar et al (2013 Proc. Comput. Cardiol. 40 297-300), was used to assess the locating accuracy. The other two indices, mean squared error of heart rate (MSE_HR) between the fetal HR signals estimated from the reference and our method (MSE_HR in bpm(2)) and root mean squared difference between the corresponding fetal RR intervals (MSE_RR in ms) were also used to assess the locating accuracy. Overall, for the maternal QRS complex, the F1 measure was 98.4% from the method without the implementation of SQA, and it was improved to 99.8% with SQA. For the fetal QRS complex, the F1 measure, MSE_HR and MSE_RR were 84.9%, 185.6 bpm(2) and 19.4 ms for the method without both SQA and FTM procedures. They were improved to 93.9%, 47.5 bpm(2) and 7.6 ms with both SQA and FTM procedures. These improvements were observed from each individual subject. It can be concluded that implementing both SQA and FTM procedures could achieve better performance for locating both maternal and fetal QRS complexes.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0967-3334/35/8/1665DOI Listing

Publication Analysis

Top Keywords

fetal qrs
20
qrs complex
16
maternal fetal
12
qrs complexes
12
abdominal ecg
12
locating maternal
12
sqa ftm
12
ftm procedures
12
fetal
9
multi-step method
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!