Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Methamphetamine is a widely abused psychostimulant containing a chiral center. Consumption of over-the-counter and prescription medications may yield positive amphetamines results, but chiral separation of l- and d-methamphetamine and its metabolite amphetamine can help determine whether the source was licit or illicit. We present the first LC-MS/MS method with precolumn derivatization for methamphetamine and amphetamine chiral resolution in plasma and oral fluid collected with the Oral-Eze(®) and Quantisal™ devices. To 0.5mL plasma, 0.75mL Oral-Eze, or 1mL Quantisal specimen racemic d11-methamphetamine and amphetamine internal standards were added, followed by protein precipitation. Samples were centrifuged and supernatants loaded onto pre-conditioned Phenomenex(®) Strata™-XC Polymeric Strong Cation solid phase extraction columns. After washing, analytes were eluted with 5% ammonium hydroxide in methanol. The eluate was evaporated to dryness and reconstituted in water. Derivatization was performed with 1-fluoro-2,4-dinitrophenyl-5-l-alanineamide (Marfey's reagent) and heating at 45°C for 1h. Derivatized enantiomer separations were performed under isocratic conditions (methanol:water, 60:40) with a Phenomenex(®) Kinetex(®) 2.6μm C18 column. Analytes were identified and quantified by two MRM transitions and their ratio on a 3200 QTrap (AB Sciex) mass spectrometer in ESI negative mode. In all three matrices, the method was linear for all enantiomers from 1 to 500μg/L, with imprecision and accuracy of ≤11.3% and 85.3-108%, respectively. Extraction efficiencies ranged from 67.4 to 117% and matrix effects from -17.0 to 468%, with variation always ≤19.1%. Authentic plasma and OF specimens were collected from an IRB-approved study that included controlled Vicks(®) VapoInhaler™ administration. The present method is sensitive, selective, economic and rapid (separations accomplished in <10min), and improves methamphetamine result interpretation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4150735 | PMC |
http://dx.doi.org/10.1016/j.chroma.2014.06.096 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!