Purpose: Dual-energy computed tomography (DECT) is an emerging imaging modality with the unique capability of determining urinary stone composition. This study compares radiation exposure of DECT, standard single-energy CT (SECT), and low-dose renal stone protocol single-energy CT (LDSECT) for the evaluation of nephrolithiasis in a single in vivo patient cohort.
Materials And Methods: Following institutional review board (IRB) approval, we retrospectively reviewed 200 consecutive DECT examinations performed on patients with suspected urolithiasis over a 6-month period. Of these, 35 patients had undergone examination with our LDSECT protocol, and 30 patients had undergone examination of the abdomen and pelvis with our SECT imaging protocol within 2 years of the DECT examination. The CT dose index volume (CTDIvol) was used to compare radiation exposure between scans. Image quality was objectively evaluated by comparing image noise. Statistical evaluation was performed using a Student's t-test.
Results: DECT performed at 80/140 kVp and 100/140 kVp did not produce a significant difference in radiation exposure compared with LDSECT (p=0.09 and 0.18, respectively). DECT performed at 80/140 kVp and 100/140 kVp produced an average 40% and 31%, respectively, reduction in radiation exposure compared with SECT (p<0.001). For patients imaged with the 100/140 kVp protocol, average values for images noise were higher in the LDSECT images compared with DECT images (p<0.001) and there was no significant difference in image noise between DECT and SECT images in the same patient (p=0.88). Patients imaged with the 80/140 kVp protocol had equivocal image noise compared with LDSECT images (p=0.44), however, DECT images had greater noise compared with SECT images in the same patient (p<0.001). Of the 75 patients included in the study, stone material was available for 16; DECT analysis correctly predicted stone composition in 15/16 patients (93%).
Conclusion: DECT provides knowledge of stone composition in addition to the anatomic information provided by LDSECT/SECT without increasing patient radiation exposure and with minimal impact on image noise.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4313790 | PMC |
http://dx.doi.org/10.1089/end.2014.0026 | DOI Listing |
J Immunother Cancer
January 2025
Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
Background: Immune checkpoint inhibitors (ICIs) in combination with antiangiogenic drugs have shown promising outcomes in the third-line and subsequent treatments of patients with microsatellite stable metastatic colorectal cancer (MSS-mCRC). Radiotherapy (RT) may enhance the antitumor effect of immunotherapy. However, the effect of RT exposure on patients receiving ICIs and targeted therapy remains unclear.
View Article and Find Full Text PDFPlant Physiol Biochem
January 2025
Centre for Nanobiotechnology, Vellore Institute of Technology, Vellore, Tamil Nadu, India. Electronic address:
The accumulation of disposable face masks (DFMs) has become a significant threat to the environment due to extensive use during the COVID-19 pandemic. In this research, we investigated the degradation of DFMs after their disposal in landfills. We replicated the potential degradation process of DFMs, including exposure to sunlight before subjecting them to synthetic landfill leachate (LL).
View Article and Find Full Text PDFJ Orthop Surg Res
January 2025
Orthopaedic Department, Assiut Faculty of Medicine, Assiut University Hospital, Assiut University, Kasr Elini Street, Number 7, P.O. Box 110, Assuit, 71515, Egypt.
Aims: Which is the best extensile lateral (ELA) or sinus tarsi (STA) approach for osteosynthesis displaced intraarticular calcaneal fracture (DIACF) is still debatable. The current RCT's primary objective was to compare the complications incidence after open reduction and internal fixation of DIACFs through STA vs. ELA.
View Article and Find Full Text PDFJ Transl Med
January 2025
Department of Cardiology, Tongji Hospital, School of Medicine, Tongji University, No. 389 Xincun Road, Shanghai, 200065, China.
Background: Heavy metal exposure is an emerging environmental risk factor linked to cardiovascular disease (CVD) through its effects on vascular ageing. However, the relationship between heavy metal exposure and vascular age have not been fully elucidated.
Methods: This cross-sectional study analyzed data from 3,772 participants in the National Health and Nutrition Examination Survey (NHANES) from 2005 to 2016.
Herz
January 2025
Faculty of Medicine, Department of Cardiology, Bilecik Şeyh Edebali University, Pelitözü Mahallesi Fatih Sultan Mehmet Blv. No. 27 Merkez, Bilecik, Turkey.
Background: The aim of this study was to compare the efficacy outcomes of the traditional Judkins left and right catheters with those of the recently introduced Tiger catheter in female participants aged 65 years and older who underwent transradial coronary angiography.
Methods: A cohort of 160 female patients aged 65 and older who were scheduled for coronary angiography (CAG) were divided into two groups according to the use of Tiger (n = 80) or Judkins (n = 80) catheters for radial angiography at a ratio of 1:1, respectively. We analyzed the effectiveness of the Tiger and Judkins catheters, the incidence of catheter failure, contrast volume, CAG time, fluoroscopy time, dose-area product (in mGy/cm), and the occurrence of radial spasm.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!