Unexceptional occurrence of tricky ECG findings in patients having new Biotronik ICDs.

Int J Cardiol

Clinique Ambroise Paré, Neuilly, France.

Published: September 2014

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijcard.2014.06.053DOI Listing

Publication Analysis

Top Keywords

unexceptional occurrence
4
occurrence tricky
4
tricky ecg
4
ecg findings
4
findings patients
4
patients biotronik
4
biotronik icds
4
unexceptional
1
tricky
1
ecg
1

Similar Publications

Background: Daily IGRT images show day-to-day anatomical variations in patients undergoing fractionated prostate radiotherapy. This is of particular importance in particle beam treatments.

Purpose: To develop a digital phantom series showing variation in pelvic anatomy for evaluating treatment planning and IGRT procedures in particle radiotherapy.

View Article and Find Full Text PDF

Global prioritization of endemic zoonotic diseases for conducting surveillance in domestic animals to protect public health.

Philos Trans R Soc Lond B Biol Sci

October 2023

Food and Agriculture Organization of the United Nations (FAO) Headquarters, Viale delle Terme di Caracalla, 00153 Rome, Italy.

Article Synopsis
  • Zoonotic diseases from domestic animals pose serious risks to human health and livelihoods, highlighting the importance of effective surveillance in animals to prevent outbreaks.
  • A study prioritized 32 zoonoses that are widespread and linked to domestic animals, emphasizing their role in transmitting infections to humans.
  • The article discusses the challenges of monitoring animal health in resource-limited settings and suggests improvements like multi-sectoral and digital surveillance approaches for better control of these diseases.
View Article and Find Full Text PDF

The electrocardiogram (ECG) interpretation in patients with implantable cardioverter defibrillator (ICD) is often a puzzling problem. The difficulty of the device function evaluation further increases in the presence of unfamiliar timing cycles and additional functions. We present an interesting ECG with a special function of a Biotronik ICD devices called the thoracic impedance monitoring, and demonstrate its behavior in a patient with atrial fibrillation, pacing beats, ventricular ectopic beats, and couple of ventricular beats.

View Article and Find Full Text PDF

The electrocardiogram (ECG) interpretation in patients with implantable pacemaker is often a perplexing problem. The difficulty in the device evaluation increases in the presence of novel timing cycles and additional functions. Authors describe a special function frequently encountered in Medtronic dual-chamber pacemakers and implantable cardioverter-defibrillator devices called managed ventricular pacing (MVP) and demonstrate its performance in the patient with undersensing episodes in ventricular channel.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!