Background: Femoral artery overlaps femoral vein by varying degrees distal to the inguinal ligament, which may result in difficult venous access and also increases the risk of arterial puncture.

Objective: To study the size of femoral vessels and the degree of overlap in children undergoing anesthesia using ultrasound at 1 and 3 cm distal to inguinal ligament.

Methods: A prospective observational study, 84 children aged <7 years were recruited in six different age groups. An experienced anesthetist identified the femoral vessels and their overlap using ultrasound at two fixed points distal to the inguinal ligament. We also evaluated the correlation of skin puncture site marked as per Advanced Paediatric Life support (APLS) guidance using landmark technique with the ultrasound location of femoral vein beneath the same site.

Results: The percentage of children with overlap of femoral vein by femoral artery increases from 5% to 60% as we move distal to the inguinal ligament. At 3 cm distal to inguinal ligament, the incidence of any degree of overlap was statistically significant (P < 0.05) in children <5 years. In 80% of children, the femoral vein was located by ultrasound beneath the skin puncture site as recommended by APLS guidelines.

Conclusion: A significant increase in femoral vein overlap occurs as we move distal to the inguinal ligament. There is one in five chance of failure to locate femoral vein by landmark technique. In children <2 years, a high approach to femoral vein cannulation under ultrasound guidance is recommended.

Download full-text PDF

Source
http://dx.doi.org/10.1111/pan.12486DOI Listing

Publication Analysis

Top Keywords

femoral artery
8
observational study
8
distal inguinal
8
relative position
4
femoral
4
position femoral
4
artery vein
4
vein children
4
children general
4
general anesthesia--an
4

Similar Publications

Evaluating cardiac performance in beagle dogs: Transesophageal echocardiography and myocardial work assessment.

Heliyon

January 2025

Department of Ultrasound Medicine, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, 210008, People's Republic of China.

Objectives: This study aimed to establish standard transesophageal echocardiographic (TEE) measurements of left ventricular (LV) morphology, function, and myocardial work parameters in healthy Beagle dogs using pressure-strain loops (PSL). Additionally, it sought to standardize optimal TEE imaging techniques and explore the potiential application of myocardial work analyis in veterinary medicine.

Methods: Thirty-seven healthy male Beagle dogs were anesthetized, intubated, and mechanically ventilated for TEE examinations.

View Article and Find Full Text PDF

Peak Procedural ACT Is Associated With All-Cause Mortality After Femoral Access PCI.

J Soc Cardiovasc Angiogr Interv

December 2024

Division of Cardiovascular Medicine, Sulpizio Cardiovascular Center, University of California San Diego, San Diego, California.

Background: A minimum threshold activated clotting time (ACT) to guide heparin dosing during percutaneous coronary intervention (PCI) is associated with lower ischemic complications. However, data are variable regarding the risk of high ACT levels. The aim of this study was to assess the impact of peak procedural ACT on complications and mortality for transfemoral and transradial access PCI.

View Article and Find Full Text PDF

A 50-year-old female presented with a 10-day history of progressive swelling and pain in the left lower extremity, ultimately diagnosed with deep vein thrombosis (DVT) and May-Thurner Syndrome (MTS). Initial ultrasound indicated thrombosis involving the left external iliac, femoral, and popliteal veins, among others. Blood tests revealed normocytic anemia, but thrombophilia screening and other blood markers were normal.

View Article and Find Full Text PDF

Purpose: The use of surgeon-modified fenestrated endograft to treat a bleeding complication in the common iliac artery.

Technique: An Endurant limb graft was modified on back table in theater after planning the fenestration using a semi-automated centerline. The Endurant stent was planned to land flush at the aortic bifurcation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!