AI Article Synopsis

  • Testing and evaluating biodetectors for biothreat agents is complex, requiring high sensitivity and low false alerts, while also being user-friendly.
  • A Standardized Reagent Bacterial Mixture (SRBM) was developed to counteract variations in airborne bacterial content, allowing for consistent and reproducible testing of biodetectors.
  • Results showed that SRBM can mimic natural bioaerosols effectively, maintaining stability for over a year, and did not compromise the detection sensitivity for specific biothreat agents, providing valuable insights for establishing testing standards.

Article Abstract

Test and evaluation of engineered biothreat agent detection systems ("biodetectors") are a challenging task for government agencies and industries involved in biosecurity and biodefense programs. In addition to user friendly features, biodetectors need to perform both highly sensitive and specific detection, and must not produce excessive false alerts. In fact, the atmosphere displays a number of variables such as airborne bacterial content that can interfere with the detection process, thus impeding comparative tests when carried out at different times or places. To overcome these bacterial air content fluctuations, a standardized reagent bacterial mixture (SRBM), consisting in a collection of selected cultivable environmental species that are prevalent in temperate climate bioaerosols, was designed to generate a stable, reproducible, and easy to use surrogate of bioaerosol sample. The rationale, design, and production process are reported. The results showed that 8.59; CI 95%: 8.46-8.72 log cfu distributed into vials underwent a 0.95; CI 95%: 0.65-1.26 log viability decay after dehydration and subsequent reconstitution, thus advantageously mimicking a natural bioaerosol sample which is typically composed of cultivable and uncultivable particles. Dehydrated SRBM was stable for more than 12months at 4°C and allowed the reconstitution of a dead/live cells aqueous suspension that is stable for 96h at +4°C, according to plate counts. Specific detection of a simulating biothreat agent (e.g. Bacillus atrophaeus) by immuno-magnetic or PCR assays did not display any significant loss of sensitivity, false negative or positive results in the presence of SRBM. This work provides guidance on testing and evaluating detection devices, and may contribute to the establishment of suitable standards and normalized procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mimet.2014.07.013DOI Listing

Publication Analysis

Top Keywords

test evaluation
8
detection systems
8
air content
8
content fluctuations
8
fluctuations standardized
8
standardized reagent
8
reagent bacterial
8
bacterial mixture
8
biothreat agent
8
specific detection
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!