A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Trending and accuracy of noninvasive hemoglobin monitoring in pediatric perioperative patients. | LitMetric

Background: Rainbow Pulse CO-Oximetry technology (Masimo Corporation, Irvine, CA) provides continuous and noninvasive measurement of arterial hemoglobin concentration (SpHb). We assessed the trending and accuracy of SpHb by this innovative monitoring compared with Hb concentration obtained with conventional laboratory techniques (Hb) in children undergoing surgical procedures with potential for substantial blood loss.

Methods: Hb concentrations were recorded from Pulse CO-Oximetry and a conventional hematology analyzer. Regression analysis and 4-quadrant plot were used to evaluate the trending for changes in SpHb and Hb measurements (ΔSpHb and ΔHb). Bias, precision, and limits of agreement of SpHb and of in vivo adjusted SpHb (SpHb - first bias to HB) compared with Hb were calculated.

Results: One hundred fifty-eight SpHb-Hb data pairs and 105 delta pairs (ΔSpHb and ΔHb) from 46 patients aged 2 months to 17 years with Hb ranging from 16.7 to 7.9 g/dL were collected. To evaluate trending, the delta pairs (ΔSpHb and ΔHb) were plotted, which revealed a positive correlation (ΔSpHb = 0.022 + 0.76ΔHb) with correlation coefficient r = 0.76, 95% CI [confidence interval] = 0.57-0.86. The bias and precision of SpHb to Hb and in vivo adjusted SpHb were 0.4 ± 1.3 g/dL and 0.1 ± 1.2 g/dL, respectively; the limits of agreement were -2.0 to 3.2 g/dL before in vivo adjustment and -2.4 to 2.2 g/dL after in vivo adjustment (P value = 0.04). The mean percent bias (from the reference Hb concentration) decreased from 4.1% ± 11.9% to 0.7% ± 11.3% (P value = 0.01). No drift in bias over time was observed during the study procedure. Of patient demographic and physiological factors tested for correlation with the SpHb, only perfusion index at sensor site showed a weak correlation.

Conclusions: The accuracy of SpHb in children with normal Hb and mild anemia is similar to that previously reported in adults and is independent of patient demographic and physiological states except for a weak correlation with perfusion index. The trending of SpHb and Hb in children with normal Hb and mild anemia showed a positive correlation. Further studies are necessary in children with moderate and severe anemia.

Download full-text PDF

Source
http://dx.doi.org/10.1213/ANE.0000000000000369DOI Listing

Publication Analysis

Top Keywords

Δsphb Δhb
12
sphb
11
trending accuracy
8
pulse co-oximetry
8
accuracy sphb
8
evaluate trending
8
bias precision
8
limits agreement
8
sphb vivo
8
vivo adjusted
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!