Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aims: We describe an alternative access approach for patients undergoing transcatheter aortic valve implantation (TAVI) using surgical cut down of the distal axillary artery, in cases wherein transfemoral access is not feasible.
Methods: From January 2012 to July 2013, 61 patients (59% men; mean age 81 ± 8 years) underwent TAVI at our institution. The mean logistic EuroSCORE and EuroSCORE II were 36 ± 24 and 14 ± 10, respectively. We assessed device success, 30-day safety and clinical efficacy using VARC II criteria.
Results: TAVI was performed with the CoreValve Revalving System (CRS) (Medtronic Inc., Minneapolis, Minnesota, USA) in all cases, using transfemoral approach in 57 patients and distal trans-axillary route in four patients. A device was successfully implanted in 94%, without any major intraprocedural complications. One case of acute kidney disease, four cases of minor vascular complication and two cases of life-threatening bleeding occurred after the procedure for pericardial bleeding requiring pericardiocentesis. Permanent pacemaker was implanted in 26% of patients. There was no instance of in-hospital mortality, while two deaths (3%) occurred in the first 30 days. The total procedure time (skin-to-skin) was longer in the trans-axillary group secondary to surgical management of access site (P = 0.027), whereas revalving and fluoroscopy time were similar (P = 0.95 and P = 0.83, respectively).
Conclusion: The location and anatomical relations of the distal axillary artery make it a safer, reproducible and operator friendly access option for TAVI.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2459/JCM.0000000000000063 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!