Determination of Tinopal CBS-X in rice papers and rice noodles using HPLC with fluorescence detection and LC-MS/MS.

Food Addit Contam Part A Chem Anal Control Expo Risk Assess

a Division of Food Additives and Packaging, Department of Food Safety Evaluation , Ministry of Food and Drug Safety , Cheongwon-gun , Chungcheongbuk-do , Korea.

Published: April 2015

To date there have been no reports of methods to determine Tinopal CBS-X. We developed a rapid and simple method to determine the Tinopal CBS-X content in rice noodles and rice papers using HPLC equipped with fluorescence detection. Heating the rice noodles and rice papers to 80°C after adding 75% methanol solution induced the release of Tinopal CBS-X from processed rice products. Tinopal CBS-X was separated using an isocratic mobile phase comprising 50% acetonitrile/water containing 0.4% tetrabutyl ammonium hydrogen sulphate at pH 8.0. The samples suspected to be positive by HPLC analysis were then confirmed by LC-MS/MS analysis. This study also investigated the Tinopal CBS-X content of three rice noodle products and two rice papers. The limits of quantification for rice papers and rice noodles were 1.58 and 1.51 µg kg(-1), respectively, and their correlation curves showed good linearity with r(2) ≥ 0.9997 and ≥ 0.9998, respectively. Moreover, rice papers had recoveries of 70.3-83.3% with precision ranging from 5.0% to 7.9%, whereas rice noodles had slightly lower recoveries of 63.4-78.7% and precisions of 8.5-11.5%. Only one rice noodle product contained Tinopal CBS-X, at around 2.1 mg kg(-1), whereas it was not detected in four other samples. Consequently, Tinopal CBS-X from rice noodles and rice papers can be successfully detected using the developed pre-treatment and ion-pairing HPLC system coupled with fluorescence detection.

Download full-text PDF

Source
http://dx.doi.org/10.1080/19440049.2014.934302DOI Listing

Publication Analysis

Top Keywords

tinopal cbs-x
32
rice papers
28
rice noodles
24
rice
16
fluorescence detection
12
noodles rice
12
cbs-x
8
cbs-x rice
8
papers rice
8
determine tinopal
8

Similar Publications

A carefully designed ammonium sulfate precipitation will simplify extraction of proteins and is considered to be a gold standard among various precipitation methods. Therefore, optimization of ammonium sulfate precipitation can be an important functional step in protein purification. The presence of high amounts of ammonium sulphate precludes direct detection of many enzymatically active proteins including reducing sugar assays (e.

View Article and Find Full Text PDF

Determination of Tinopal CBS-X in rice papers and rice noodles using HPLC with fluorescence detection and LC-MS/MS.

Food Addit Contam Part A Chem Anal Control Expo Risk Assess

April 2015

a Division of Food Additives and Packaging, Department of Food Safety Evaluation , Ministry of Food and Drug Safety , Cheongwon-gun , Chungcheongbuk-do , Korea.

To date there have been no reports of methods to determine Tinopal CBS-X. We developed a rapid and simple method to determine the Tinopal CBS-X content in rice noodles and rice papers using HPLC equipped with fluorescence detection. Heating the rice noodles and rice papers to 80°C after adding 75% methanol solution induced the release of Tinopal CBS-X from processed rice products.

View Article and Find Full Text PDF

An exact control-versus-treatment comparison test based on ranked set samples.

Biometrics

December 2009

Department of Statistics, The Ohio State University, 1958 Neil Avenue, Columbus, Ohio 43210, USA.

A control-versus-treatment multiple comparison test procedure is developed based on ranked set samples. The test, constructed based on K-independent exact median confidence intervals corresponding to the K populations, rejects the null hypothesis of equal medians if the median confidence intervals of the control group and any one of the other K - 1 treatment groups are disjoint. The use of the proposed test is illustrated with data from an agricultural experiment.

View Article and Find Full Text PDF

A method to estimate reactive transport parameters as well as geometric conduit parameters from a multitracer test in a karst aquifer is provided. For this purpose, a calibration strategy was developed applying the two-region nonequilibrium model CXTFIT. The ambiguity of the model calibration was reduced by first calibrating the model with respect to conservative tracer breakthrough and later transferring conservative transport parameters to the reactive model calibration.

View Article and Find Full Text PDF

Assessment of dermal pesticide exposure with fluorescent tracer: a modification of a visual scoring system for developing countries.

Ann Occup Hyg

January 2006

Department of Preventive Medicine and Public Health, Occupational and Environmental Health Program, Faculty of Medicine, UNAN-León, Nicaragua.

A semi-quantitative dermal exposure assessment method based on visual observations of fluorescence images was presented by Fenske in 1988. We adapted the method to Nicaraguan working conditions and evaluated its performance. Thirty-two farmers applied chlorpyrifos and methamidophos marked with Tinopal CBS-X(R).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!