Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Backgrounds: Osteopontin (OPN) has been reported as one of the most promising markers for hepatocellular carcinoma (HCC). The goal of this meta-analysis was to evaluate the clinical value of the plasma OPN versus alpha-fetoprotein (AFP) in the diagnosis of HCC.
Methods: A comprehensive literature search of PubMed, Foreign Medical Journal Service, Chinese Science Journals Database, and Google Scholar was conducted on articles published before 1st October 2013. The sensitivity, specificity, and other measures of accuracy of OPN in the diagnosis of HCC were pooled using random effects models. The methodological quality of each study was assessed by QUADAS (quality assessment for studies of diagnostic accuracy). Statistical analysis was performed by employing Meta-Disc 1.4 and Stata, version 12. Summary receiver operating characteristic curves were used to summarize overall test performance.
Results: Seven studies were included in our meta-analysis. The summary estimates for OPN and AFP in the diagnosis of HCC in these studies as follows: sensitivity, 0.86 (0.79-0.91) vs 0.66 (0.53-0.76), specificity, 0.86 (0.69-0.94) vs 0.95 (0.87-0.98), positive likelihood ratio (PLR), 6.10 (2.43-15.32) vs 13.25 (4.69-37.49), negative likelihood ratio (NLR), 0.16 (0.09-0.28) vs 0.36 (0.26-0.51), diagnostic odds ratio (DOR), 38.52 (8.99-165.08) vs 36.75 (11.04-122.32), and the area under the curve (AUC), 0.92 vs 0.87.
Conclusion: Our study demonstrates that OPN has a comparable accuracy to AFP for the diagnosis of HCC, while the value of OPN in combination with AFP for HCC detection deserves further investigation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.clinre.2014.06.008 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!