Background: For the evaluation of severely injured trauma patients a variety of total body computed tomography (CT) scanning protocols exist. Frequently multiple pass protocols are used. A split bolus contrast protocol can reduce the number of passes through the body, and thereby radiation exposure, in this relatively young and vitally threatened population.
Purpose: To evaluate three protocols for single pass total body scanning in 64-slice multidetector CT (MDCT) on optimal image quality.
Material And Methods: Three total body CT protocols were prospectively evaluated in three series of 10 consecutive trauma patients. In Group A unenhanced brain and cervical spine CT was followed by chest-abdomen-pelvis CT in portovenous phase after repositioning of the arms. Group B underwent brain CT followed without arm repositioning by a one-volume contrast CT from skull base to the pubic symphysis. Group C was identical to Group A, but the torso was scanned with a split bolus technique. Three radiologists independently evaluated protocol quality scores (5-point Likert scale), parenchymal and vascular enhancement and artifacts.
Results: Overall image quality was good (4.10) in Group A, more than satisfactory (3.38) in Group B, and nearly excellent (4.75) in Group C (P < 0.001). Interfering artifacts were mostly reported in Group B in the liver and spleen.
Conclusion: In single pass total body CT scanning a split bolus technique reached the highest overall image quality compared to conventional total body CT and one-volume contrast CT.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/0284185114539319 | DOI Listing |
Radiologia (Engl Ed)
October 2024
Servicio de Radiodiagnóstico, Hospital Universitario Central de Asturias, Oviedo, Spain.
Iodinated contrast is administered when carrying out computed tomography (CT) scans to define anatomical structures and detect pathologies. The contrast is administered according to different protocols which vary significantly and include vascular, visceral, multiphasic and split-bolus injection studies. Each protocol has its own indications and particularities to optimise the use of the contrast medium in each situation.
View Article and Find Full Text PDFPediatr Radiol
November 2024
University Hospital of Lausanne, Rue de Bugnon 21, CH-1011, Lausanne, Vaud, Switzerland.
We present here a user-friendly calculator for the setting of a pediatric split-bolus polytrauma computed tomography (CT) protocol with a mixed arterial and venous phase, aiming to both reduce radiation dose and improve workflow while assuring optimal image quality. All the different parameters are calculated based on patient's weight with rapid computation of the injected contrast media and saline volumes, injection's flow rate, injection's timing, and optimal acquisition time. The designed calculator is built in a widely available Google Sheets file, accessible by a quick response (QR) code.
View Article and Find Full Text PDFUpdates Surg
October 2024
Department of General Surgery, Endocrinology, Orthopedics and Rehabilitation, Federico II University of Naples, Naples, Italy.
Indian J Radiol Imaging
July 2024
Department of Neurosurgery, Sree Chitra Tirunal Institute for Medical Sciences & Technology, Thiruvananthapuram, India.
: Despite documented correlation between glioma grades and dynamic contrast-enhanced (DCE) magnetic resonance (MR) perfusion-derived parameters, and its inherent advantages over dynamic susceptibility contrast (DSC) perfusion, the former remains underutilized in clinical practice. Given the inherent spatial heterogeneity in high-grade diffuse glioma (HGG) and assessment of different perfusion parameters by DCE (extravascular extracellular space volume [Ve] and volume transfer constant in unit time [k-trans]) and DSC (rCBV), integration of the two into a protocol could provide a holistic assessment. Considering therapeutic and prognostic implications of differentiating WHO grade 3 from 4, we analyzed the two grades based on a combined DCE and DSC perfusion.
View Article and Find Full Text PDFIntroduction: In 2022, updated guidance from NICE expanded the options for self-monitoring of blood glucose for patients with type 2 diabetes (T2DM), to include continuous glucose monitoring (CGM). In this budget impact analysis, the cost impact of CGM was compared with traditional self-monitoring of blood glucose (SMBG) in adults with T2DM over 1 year from the commissioner perspective in England.
Research Design And Methods: The NICE-eligible T2DM cohort was split into 4 subgroups to enable nuanced costing by insulin administration frequency: basal human insulin, premixed insulin, basal-bolus insulin and bolus insulin.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!