Purpose: Because there is a paucity of clear-cut evidence regarding which materials and techniques are most accurate for complete-arch, multiple-implant impressions, the current study sought to analyze the data and draw useful conclusions based on the evidence for application in clinical practice.

Materials And Methods: Relevant studies published between 1990 and December 2012 were included in the review. The articles were located through PubMed and manually through reviewing references in the literature. Papers examining implant impression accuracy in completely edentulous arches (three or more implants) were included. Clinical case reports, technique articles, abstracts, and review papers were excluded.

Results: One of the 34 studies selected for evaluation was clinical; the remaining 33 were in vitro investigations. Ten studies compared polyvinyl siloxane (PVS) and polyether (PE); eight found that these were statistically equal in terms of impression accuracy. The splint effect was examined by 24 studies; 10 failed to observe any differences between splinted and nonsplinted impressions, whereas 7 (> 25%) showed that the splinted technique was better than the nonsplinted technique. Thirteen studies investigated the differences between pickup and transfer impression techniques; six favored pickup over transfer, and five found insignificant differences between the techniques. The effect of nonparallel implants on edentulous multiple-implant impression accuracy was examined by only two studies. Significant differences in accuracy were observed for 15 degrees of angulation.

Conclusion: Most of the evidence supports PVS and PE as the most accurate impression materials for edentulous multiple-implant situations, with no clear advantage of either. Conflicting evidence exists regarding the most accurate impression technique (splinted/nonsplinted, pickup/transfer), and no clear recommendation can be made. Inadequate research exists regarding several other factors that might affect edentulous implant impression accuracy. There is a lack of clinical research to support in vitro findings.

Download full-text PDF

Source
http://dx.doi.org/10.11607/jomi.3233DOI Listing

Publication Analysis

Top Keywords

impression accuracy
16
implants edentulous
8
implant impression
8
examined studies
8
pickup transfer
8
edentulous multiple-implant
8
accurate impression
8
impression
7
accuracy
6
studies
6

Similar Publications

Background/purpose: The performance of intraoral scanners (IOSs) relies on the operator's skills. However, whether operator experience influences IOS accuracy remains unclear. This study investigated the effect of operator experience on the trueness accuracy and time-based efficiency of IOSs.

View Article and Find Full Text PDF

Aim: This study investigated the accuracy of intraoral scanner (IOS) based on different image acquisition technologies in the field of presurgical-orthopedictreatment (PSOT) in neonates with cleft.

Methods: Dental cast models of clinical situations representing unilateral cleft-lip-palate(UCLP), bilateral cleft-lippalate( BCLP) and cleft-palate(CP) with reference PEEK-scanbodies (Cares RC Mono-Scankörper, Straumann, Switzerland) were scanned utilizing four IOS systems: CareStream-CS3600®(CS), Medit-i500®(MD), Cerec-Omnicam®(SO), 3Shape-Trios-3®(TS). One calibrated operator made 5 scans from each model using each IOS (N=60).

View Article and Find Full Text PDF

Purpose: This in vitro study investigates the accuracy of digital impressions taken with different dental materials. It compares the scan accuracy and trueness of a handheld scanner operated by an experienced clinician, a handheld scanner operated by a robotic arm, and a tabletop scanner. By measuring the number of triangles, average degree, and vertices within the three groups, conclusions about the accuracy of different scanning methods on digital models can be drawn.

View Article and Find Full Text PDF

Aims And Background: This study aimed to assess the accuracy of digital intraoral scans in capturing the three-dimensional (3D) surface of teeth and dental arches in mixed dentition, compared with conventional plaster models. Intraoral scanning technology has seen rapid advancements in recent years, revolutionizing orthodontic and dental practices. However, its accuracy in mixed dentition remains a subject of investigation.

View Article and Find Full Text PDF

Low-Waste Technology for High-Precision Connecting Rod Forging Manufacturing.

Materials (Basel)

January 2025

Department of Metal Forming, Welding and Metrology, Wroclaw University of Science and Technology, Lukasiewicza Street 5, 50-370 Wroclaw, Poland.

This study refers to the application of an advanced tool in the form of numerical modelling in order to develop a low-waste hot die forging technology to produce a connecting rod forging. The technology aims at ensuring a limited amount of the charge material is necessary to produce one forging, as well as minimizing forging forces, and thus the electric energy consumption. The study includes a verification of the current production technology, which constituted the basis for the construction and development of a numerical model.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!