The purpose of this study was to establish the internal consistency and test-retest reliability of the electromyographic and accelerometric data sampled from the prime movers of the dominant arm during an antigravity, within-arm's length stand-reaching task without trunk restraint. Ten healthy young adults participated in two experimental sessions, approximately 7-10days apart. During each session, subjects performed 15 trials of both a flexion- and an abduction-reaching task. Surface EMG and acceleration using wireless sensors were sampled from the anterior and middle deltoid. Reliability was established using Cronbach's alpha, intraclass correlation coefficients (ICC 2, k) and standard error of measurements (SEM) for electromyographic reaction time, burst duration and normalized amplitude along with peak acceleration. Results indicated high degrees of inter-trial and test-retest reliability for flexion (Cronbach's α range=0.92-0.99; ICC range=0.82-0.92) as well as abduction (Cronbach's α range=0.94-0.99; ICC range=0.81-0.94) reaching. The SEM associated with response variables for flexion and abduction ranged from 1.55-3.26% and 3.33-3.95% of means, respectively. Findings from this study revealed that electromyographic and accelerometric data collected from prime movers of the arm during the relatively functional stand-reaching task were highly reproducible. Given its high reliability and portability, the proposed test could have applications in clinical and laboratory settings to quantify upper limb function.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jelekin.2014.05.011 | DOI Listing |
Med Phys
January 2025
OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany.
Background: Patient-specific quality assurance (PSQA) is a crucial yet resource-intensive task in proton therapy, requiring special equipment, expertise and additional beam time. Machine delivery log files contain information about energy, position and monitor units (MU) of all delivered spots, allowing a reconstruction of the applied dose. This raises the prospect of phantomless, log file-based QA (LFQA) as an automated replacement of current phantom-based solutions, provided that such an approach guarantees a comparable level of safety.
View Article and Find Full Text PDFJ Oral Pathol Med
January 2025
Laboratory of Oral Histopathology, Health Sciences Faculty, University of Brasília, Brasília, Brazil.
Background: Cell culture studies play an important role in addressing fundamental scientific questions. However, inadequate reporting of these studies results in a lack of transparency and reproducibility. Recognizing the need for improvement, several ongoing efforts, such as CRIS guidelines and the ICLAC checklist, are focused on enhancing best practices for in vitro studies.
View Article and Find Full Text PDFNat Commun
January 2025
Institute for Experimental Immunology and Imaging, University Hospital Essen, Essen, Germany.
Multimodal imaging by matrix-assisted laser desorption ionisation mass spectrometry imaging (MALDI MSI) and microscopy holds potential for understanding pathological mechanisms by mapping molecular signatures from the tissue microenvironment to specific cell populations. However, existing software solutions for MALDI MSI data analysis are incomplete, require programming skills and contain laborious manual steps, hindering broadly applicable, reproducible, and high-throughput analysis to generate impactful biological discoveries. Here, we present msiFlow, an accessible open-source, platform-independent and vendor-neutral software for end-to-end, high-throughput, transparent and reproducible analysis of multimodal imaging data.
View Article and Find Full Text PDFJ Voice
January 2025
Department of Otorhinolaryngology, Hospital of Chengdu University of Traditional Chinese Medicine, Chengdu, China. Electronic address:
Objective: The Mandarin Chinese version of the Vocal Performance Questionnaire (VPQ-CM) for evaluating vocal performance.
Methods: A total of 120 participants with vocal disorders and 120 healthy participants completed this study. Investigators translated the original VPQ into the VPQ-CM, and participants completed the questionnaire fill it.
Neuroimage
January 2025
Center for Mind/Brain Sciences (CIMeC), University of Trento, 38068, Rovereto, (TN), Italy.
Transcranial magnetic stimulation (TMS) has the potential to yield insights into cortical functions and improve the treatment of neurological and psychiatric conditions. However, its reliability is hindered by a low reproducibility of results. Among other factors, such low reproducibility is due to structural and functional variability between individual brains.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!