A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a gas chromatography-mass spectrometry method for the quantification of glucaric Acid derivatives in beverage substrates. | LitMetric

Development of a gas chromatography-mass spectrometry method for the quantification of glucaric Acid derivatives in beverage substrates.

Int J Anal Chem

Chemir Analytical Services, 2672 Metro Boulevard, Maryland Heights, MO 63043, USA.

Published: July 2014

A gas chromatography-mass spectrometry (GC-MS) method using the standard addition methodology was developed for the determination of glucuronolactone (GL) and glucuronic acid (DGuA) in four beverages categorized as detoxification, recovery, or energy drinks. The method features a precolumn derivatization step with a combination of BSTFA (N,O-bis(trimethylsilyl)trifluoroacetamide) and TMCS (trimethylchlorosilane) to silylate the analytes. The sample pretreatment required no extraction, filtration, or reduction step prior to the injection. The quantification of the analytes was performed using a five-point standard addition protocol. The proposed method presented excellent intraday precision (%RSD < 10) and linearity for GL calibration curves (correlation coefficients > 0.995) and acceptable linearity for DGuA calibration curves (correlation coefficients > 0.97). The estimated limits of detection (LOD) and quantification (LOQ) for GL ranged from 0.006 ppm to 0.14 ppm, and 0.02 ppm to 0.47 ppm, respectively. The estimated LOD and LOQ for DGuA determination ranged, respectively, from 0.06 ppm to 1.1 ppm and 0.2 ppm to 3.8 ppm. The results demonstrated that the method should be regarded as a reliable alternative to the simultaneous determination of GL and DGuA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4082866PMC
http://dx.doi.org/10.1155/2014/402938DOI Listing

Publication Analysis

Top Keywords

gas chromatography-mass
8
chromatography-mass spectrometry
8
standard addition
8
calibration curves
8
curves correlation
8
correlation coefficients
8
method
5
development gas
4
spectrometry method
4
method quantification
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!