Pulse pressure relation to aortic and left ventricular structure in the Age, Gene/Environment Susceptibility (AGES)-Reykjavik Study.

Hypertension

From the Cardiovascular Engineering, Inc, Norwood, MA (A.A.T., J.D.G., V.B.); Icelandic Heart Association, Kopavogur, Iceland (S.S., T.A., V.G.); Leiden University Medical Center, Leiden, The Netherlands (J.J.M.W., A.d.R.); University of Iceland, Reykjavik, Iceland (T.A., V.G.); and National Institute on Aging, National Institutes of Health, Bethesda, MD (L.J.L., T.B.H.).

Published: October 2014

High pulse pressure, a major cardiovascular risk factor, has been attributed to medial elastic fiber degeneration and aortic dilation, which transfers hemodynamic load to stiffer collagen. However, recent studies suggest higher pulse pressure is instead associated with smaller aortic diameter. Thus, we sought to elucidate relations of pulse pressure with aortic stiffness and aortic and cardiac dimensions. We used magnetic resonance imaging to examine relationships of pulse pressure with lumen area and wall stiffness and thickness in the thoracic aorta and left ventricular structure in 526 participants (72-94 years of age, 295 women) in the community-based Age, Gene/Environment Susceptibility-Reykjavik Study. In a multivariable model that adjusted for age, sex, height, weight, and standard vascular risk factors, central pulse pressure had a negative relationship with aortic lumen area (all effects expressed as mm Hg/SD; B=-8.1±1.2; P<0.001) and positive relationships with left ventricular end-diastolic volume (B=3.8±1.0; P<0.001), carotid-femoral pulse wave velocity (B=3.6±1.0; P<0.001), and aortic wall area (B=3.0±1.2; P=0.015). Higher pulse pressure in older people is associated with smaller aortic lumen area and greater aortic wall stiffness and thickness and left ventricular volume. Relationships of larger ventricular volume and smaller aortic lumen with higher pulse pressure suggest mismatch in hemodynamic load accommodation by the heart and aorta in older people.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4162768PMC
http://dx.doi.org/10.1161/HYPERTENSIONAHA.114.03870DOI Listing

Publication Analysis

Top Keywords

pulse pressure
24
left ventricular
8
ventricular structure
8
age gene/environment
8
lumen area
8
pulse
6
aortic
6
pressure
5
pressure relation
4
relation aortic
4

Similar Publications

This was an original article, and the objective of this study was to investigate the effects of bipolar transurethral plasma kinetic prostatectomy (TUPKP) on urodynamics and sexual function in benign prostatic hyperplasia (BPH) patients. One hundred and four BPH patients were divided into a control group and an intervention group. The control group received transurethral resection of prostate, while the intervention group received TUKEP.

View Article and Find Full Text PDF

A highly sensitive sulfur dioxide (SO) photoacoustic gas sensor was developed for the sulfur hexafluoride (SF) decomposition detection in electric power systems by using a novel 266 nm low-cost high-power solid-state pulse laser and a high -factor differential photoacoustic cell. The ultraviolet (UV) pulse laser is based on a passive -switching technology with a high output power of 28 mW. The photoacoustic signal was normalized to the laser power to solve the fluctuation of the photoacoustic signal due to the power instability of the UV laser.

View Article and Find Full Text PDF

Angiotensin-converting enzyme (ACE) is a key regulator of blood pressure, and ACE inhibition is an essential part of the treatment of hypertension. We used a molecular docking approach to find the interaction of ACE with an active flavonoid isolated from Linn, , which leads to potential antihypertensive effects in methyl predenisolone-induced hypertensive rats. Additionally, the pharmacokinetic parameters of this compound are assessed.

View Article and Find Full Text PDF

Cyclovirobuxine D, a natural compound derived from the medicinal plant Buxus sinica, demonstrates a diverse array of therapeutic benefits, encompassing anti-arrhythmic properties, blood pressure regulation, neuronal protection, and anti-ischemic activity. However, its limited solubility hinders the bioavailability of current oral and injectable formulations, causing considerable adverse reactions and toxicity. In this investigation, we embarked on an unprecedented exploration of the skin penetration potential of cyclovirobuxine D utilizing chemical penetration enhancers and niosomes as innovative strategies to enhance its dermal absorption.

View Article and Find Full Text PDF

Powder-based hemostatic materials have offered unprecedented opportunities for the effective sealing and repair of irregularly shaped wounds and high-pressure, noncompressible arterial bleeding wounds caused by surgeries, traffic accidents, and wartime injuries. However, inadequate adhesion to bleeding wounds and poor hemostasis in biological tissues remains challenging. Herein, we report a self-gelling hemostatic powder based on polyacrylic acid/polyethyleneimine/polyethylene glycol (named PPG) for rapid hemostasis and effective antibacterial ability.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!