Purpose: To assess the feasibility of fitting a lathed soft toric contact lens (STCL) after the implant of intrastromal corneal ring segments (ICRSs) to treat keratoconus.
Methods: Six months after ICRS implantation, 47 eyes of 47 patients (18-45 years) were fitted with a STCL. In each eye, we determined refractive error, uncorrected (UDVA) and corrected distance visual acuity (CDVA), and keratometry and asphericity measures. The outcome of STCL fitting was defined according to CDVA as successful (≤0.2logMAR) or unsuccessful (>0.2logMAR). Patients in the unsuccessful group were refitted with a piggy-back (PB) system. The above variables and the change in CDVA observed after STCL and PB lens fitting from spectacle CDVA were compared in the two groups.
Results: STCL fitting was successful in 75%, 66.66% and 0% of the ICRS implanted eyes with stages I-III keratoconus, respectively. Spectacle-CDVA was 1.5 lines better and mean corneal power was 3.62D lower in the successful STCL group. In this group, the difference in cylinder axis between spectacles and STCL was 24.25° lower. PB refitting achieved a PB-CDVA ≤0.2logMAR in all cases. A similar difference in the CDVA change achieved by contact lenses versus spectacles was observed in the successful STCL and PB refitted groups.
Conclusion: STCL fitting is a feasible option in a large proportion of patients implanted with ICRS. When these lenses are unsatisfactory, a PB system is a good alternative.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.clae.2014.06.001 | DOI Listing |
Cont Lens Anterior Eye
April 2022
Faculty of Optics and Optometry, Complutense University of Madrid, Spain.
Objectives: To assess the feasibility of fitting soft toric contact lenses (STCL) in corneal ectasias and their impact on optical quality and visual performance.
Methods: A total of 22 eyes were fitted with a molded STCL: 11 eyes/9 subjects with corneal ectasia and 11 healthy eyes/11 subjects. Wavefront aberrations were analyzed using a Hartmann-Shack aberrometer.
Cont Lens Anterior Eye
October 2019
Yıldırım Beyazıt University, Ankara Atatürk Training and Research Hospital, Ophthalmology Department, Üniversiteler Mahallesi Bilkent Caddesi No: 1, Ankara, Turkey. Electronic address:
Purpose: To compare the clinical and topographical findings of the keratoconus patients according to the prescribed contact lens type and to investigate the effects of corneal collagen cross-linking (CXL) and cone location on lens selection.
Methods: The records of 301 eyes of 195 keratoconus patients who were prescribed contact lenses were analyzed retrospectively. The eyes were grouped according to the lens type: Soft toric contact lens (STCL), rigid gas-permeable contact lens (RGPCL), hybrid contact lens (HCL) and mini-scleral contact lens (MSCL).
Cont Lens Anterior Eye
October 2014
Hospital Clinico San Carlos, 28037 Madrid, Spain.
Purpose: To assess the feasibility of fitting a lathed soft toric contact lens (STCL) after the implant of intrastromal corneal ring segments (ICRSs) to treat keratoconus.
Methods: Six months after ICRS implantation, 47 eyes of 47 patients (18-45 years) were fitted with a STCL. In each eye, we determined refractive error, uncorrected (UDVA) and corrected distance visual acuity (CDVA), and keratometry and asphericity measures.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!